Thursday, November 4, 2010

Midea Error Code


Part1. Outdoor Error Code Explanation

Display = E1
Malfunction or Protection = Phase Protection

Display = E2
Malfunction or Protection = Communication error between indoor units and outdoor unit

Display = E3
Malfunction or Protection = Outdoor tube temperature sensor T3 malfunction

Display = E4
Malfunction or Protection = Outdoor ambient temperature sensor T4 malfunction

Display = E5
Malfunction or Protection = Digital discharge temperature sensor T5 malfunction

Display = E6
Malfunction or Protection = Outdoor tube temperature sensor T3B malfunction

Display = E9
Malfunction or Protection = Voltage error

Display = H1
Malfunction or Protection = Communication malfunction between chips

Display = H2
Malfunction or Protection = Quantity of MS lessen (recovered by cut off the power)

Display = P1
Malfunction or Protection = Hi-pressure protection

Display = P2
Malfunction or Protection = Low-pressure protection

Display = P3
Malfunction or Protection = Digital compressor current protection

Display = P4
Malfunction or Protection = Digital compressor discharge temperature protection

Display = P5
Malfunction or Protection = Outdoor condenser high temperature protection

Display = P7
Malfunction or Protection = Current protection, No.1 fixed compressor

Display = dF
Malfunction or Protection = Defrosting

MSC-18HRIN1; MSH-18HRIN1
MSE-09HRIN2; MSE-12HRIN2

Indoor Unit Error Display
Display LED STATUS
E0 EEPROM error
E1 Indoor / outdoor units communication protection
E2 Zero-crossing examination error
E3 Fan speed beyond control
E5 Open or short circuit of outdoor temperature sensor
E6 Room temperature or evaporator temperature sensor open or short circuit of
P0 Module protection
P1 Over voltage or too low voltage protection
P2 Compressor top protection against temperature
P3 Outdoor low temp. protection
P4 Inverter compressor drive error

Kindly Bookmark this Post using your favorite Bookmarking service:
Technorati Digg This Stumble Stumble Facebook Twitter

22 komentar:

Xzo on December 28, 2012 at 2:37 AM said...

So with operation and defrost blinking continuously on indoor unit, it would be error e6 right? Its midea msg09hrn1.
Thanks

Yiannis papayiannis on June 3, 2013 at 11:07 AM said...

Hello ,my midea has an error code P0 what is the cause and how can i fix it....please!Thanks.

mohd shmth on January 10, 2015 at 11:26 AM said...

Error code E24?

esteban on January 19, 2015 at 1:48 PM said...

my midea mga-f30w/s show "EC" in lcd (interior unit) and "E2" in display of motherboard (exterior unit). help please!

sargam india on April 8, 2015 at 4:11 AM said...

Buy AC Online from Sargam Electronics.
Get Air Conditioner, Air Conditioner price list and best Air Conditioner in Delhi
at Lowest price. C.O.D & EMI's available. than follows our website
ac in delhi

ivanlim on May 29, 2015 at 10:26 PM said...

E3 how

mnpreet brar smalsar on June 21, 2015 at 8:18 AM said...

If indoor unit showing E3 it means fan speed beyond the control . Most probably electronic control board will be a faulty

Malcolm Skinner on January 29, 2016 at 10:54 PM said...

Midea aircon model CR002 RG05D4 202055090978 showing an E1 on panel how do i fix it

Adelani Azeez on March 23, 2016 at 1:05 PM said...

We error code what can cause it and solution?

Adelani Azeez on March 23, 2016 at 1:07 PM said...

Error code EE .

Artan Roko on April 7, 2016 at 9:17 AM said...

Midea Type MGFA-48ARN1 show in display P11.
Could you suggestion me, how to fix it?

Mick Gooan on April 16, 2016 at 8:08 PM said...

So what component would be likely to cause a E9 fault. Unit model is MSK24M3 split system

Mick Gooan on April 16, 2016 at 8:09 PM said...

So what component would be likely to cause a E9 fault. Unit model is MSK24M3 split system

محمد الوائلي on June 8, 2016 at 7:59 AM said...

hi the device display p7 how to fix it

rambo labuan on July 1, 2016 at 10:54 AM said...

Mine, the error code is E3 the technician come with new outdoor fan motor. The problem still not settle.

Imad hijjaj on July 6, 2016 at 6:02 PM said...

P12

Unknown on July 9, 2016 at 8:32 PM said...

EC led display in room air conditioner. What's happening?

Dr. Arsenio Jr. or Dr. Jen Lim on August 26, 2016 at 6:54 PM said...

hello , I have P7 error on mfj36CR model. what is the problem?

Unknown on November 9, 2016 at 8:56 AM said...

hello,i have midea mission model 12 btu which work perfect but
after 1 hour it stops and bleeping 88 can some one help me pls tks

Eva's Krstic on November 13, 2016 at 1:55 PM said...

hello I have a problem I have split air condition Midea MSR-24HR model (R6) she works on heating after a while we phenomenon on the screen red light and that's when the # symbol of this electricity is poor me a 180 volt air conditioner is operating at 220 whether it is a problem ?

Renemir Tolentino on January 13, 2017 at 12:05 AM said...

P10 error on MFJ-36CR . What is the problem

Unknown on May 2, 2017 at 11:13 AM said...

P12