OUTDOOR UNIT
YHUJYH024BAR-A-X
YHUJYH028BAR-A-X
YHUJYH036BAR-A-X
YHUJYH048BAR-A-X
YHUJYH048BAS-A-X
YHUJYH060BAS-A-X
Diagnostic code for outdoor unit YHUJYH024BAR-A-X
Flash times of LED on mainboard = 1
Trouble description = Eeprom failure
Analyze and diagnose = Outdoor main board eeprom fail
Flash times of LED on mainboard = 2
Trouble description = IPM failure
Analyze and diagnose = IPM failure
Flash times of LED on mainboard = 4
Trouble description = Communication error between main board and spdu module SPDU Communicition error
Analyze and diagnose = Communication fail over 4 min
Flash times of LED on mainboard = 5
Trouble description = High pressure protection
Analyze and diagnose = System high pressure over 4.15 Mpa
Flash times of LED on mainboard = 6
Trouble description = Module over-voltage protection(only for Spdu) Module lack-voltage protection(only for Spdu)
Analyze and diagnose = Send from Spdu module
Flash times of LED on mainboard = 8
Trouble description = Compressor discharging temperature protection
Analyze and diagnose = Compressor discharging temperature over 110 centigrade
Flash times of LED on mainboard = 9
Trouble description = Abnomal of DC motor
Analyze and diagnose = jam of DC motor or motor failure
Flash times of LED on mainboard = 10
Trouble description = Abnomal of pipe sensor
Analyze and diagnose = Piping sensor short-circuit or open-circuit
Flash times of LED on mainboard = 12
Trouble description = Abnomal of outdoor ambient sensor
Analyze and diagnose = Outdoor ambient sensor short-circuit or open-circuit
Flash times of LED on mainboard = 13
Trouble description = Abnormal of compressor dischage sensor
Analyze and diagnose = Compressor discharging sensor short-circuit or open-circuit
Flash times of LED on mainboard = 15
Trouble description = Communication error between indoor and outdoor unit
Analyze and diagnose = Communication fail over 4 min
Flash times of LED on mainboard = 16
Trouble description = Lack of refrigerant
Analyze and diagnose = check if there is leakage in the unit
Flash times of LED on mainboard = 17
Trouble description = 4-way valve reverse failure
Analyze and diagnose = Alarm and stop if detect Td-Tci<=15 last for 1min after compressor has started for 10min in heating mode, confirm the failure if it appears 3 times in one hour
Flash times of LED on mainboard = 18
Trouble description = Compressor jam (ony for spdu )
Analyze and diagnose = Inner compressor is abnormal jamed
Flash times of LED on mainboard = 19
Trouble description = Module EEV select circuit error
Analyze and diagnose = Module EEV select wrong circuit
Flash times of LED on mainboard = 25
Trouble description = Compressor U-phase over-current
Analyze and diagnose = The current of compressor U-phase is too high
Flash times of LED on mainboard = 25
Trouble description = Compressor V-phase over-current
Analyze and diagnose = The current of compressor V-phase is too high
Flash times of LED on mainboard = 25
Trouble description = Compressor W-phase over-current
Analyze and diagnose = The current of compressor W-phase is too high
Flash times of LED on mainboard = 45
Trouble description = Low pressure protection
Analyze and diagnose = System over pressure under 0.05Mpa
YHUJYH024BAR-A-X YHUJYH028BAR-A-X YHUJYH036BAR-A-X YHUJYH048BAR-A-X
YHUJYH048BAS-A-X YHUJYH060BAS-A-X
PRODUCT DIAGNOSIS PROCEDURE
Malfunction Code = 1
Trouble Description = EEPROM faulty
Analyze and diagnose =
Remark = Non-resumable
Malfunction Code = 2
Trouble Description = Over current protection in course of compressor frequency going down detected by software
Analyze and diagnose = If it occurs 3 times in 1 hour, confirm the failure, the former twice will not alarm
Remark = Non-resumable resumable
Malfunction Code = 3
Trouble Description = protection of over current in course of compressor fixed speed operation
Analyze and diagnose = Module abnormal, if it occurs 3 times in 1 hour, confirm the failure
Remark = Non-resumable
Malfunction Code = 4
Trouble Description = Communication abnormal between connecting board and module
Analyze and diagnose = It can not get the feedback from module after communicating for 4 minutes
Remark = resumable
Malfunction Code = 5
Trouble Description = Compressor overcurrent
Analyze and diagnose = If it occurs 3 times in 1 hour, confirm the failure, the former twice will not alarm
Remark = Non-resumable
Malfunction Code = 7
Trouble Description = Compressor blocked or abnormal operation
Analyze and diagnose = If it occurs 3 times in 1 hour, confirm the failure, the former twice will not alarm
Remark = Non-resumable
Malfunction Code = 8
Trouble Description = Protection of discharging temp. too high
Analyze and diagnose = After compressor starts up, if TD is over 115 , 10 seconds later compressor stops, if it occurs 3 times in 1 hour, confirm the failure
Remark = Non-resumable
Malfunction Code = 9
Trouble Description = DC fan motor faulty
Analyze and diagnose = If it occurs 3 times in 1 hour, confirm the failure, the former
twice will not alarm
Remark = Non-resumable
Malfunction Code = 10
Trouble Description = Outdoor defrosting temp. sensor abnormal
Analyze and diagnose = Sensor is detected below 20 or over 1000 for 60 seconds, but in cooling mode,this sensor failure will not be dealt with,and in defrosting or within 6 minutes after defrosting,it will not alarm
Remark = resumable
Malfunction Code = 11
Trouble Description = Suction temp.sensor abnormal
Analyze and diagnose = If it occurs 3 times in 1 hour, confirm the failure, the former twice will not alarm
Remark = resumable
Malfunction Code = 12
Trouble Description = Ambient temp. sensor abnormal
Analyze and diagnose = Sensor is detected below 20 or over 1000 for 60 seconds, but in frosting or within 6 minutes after defrosting, it will not alarm
Remark = resumable
Malfunction Code = 13
Trouble Description = Discharging temp. sensor abnormal
Analyze and diagnose = After compressor running for 3 minutes, Sensor is detected below
20 or over 1000 for 60 seconds
Remark = resumable
Malfunction Code = 15
Trouble Description = communication between indoor and outdoor abnormal
Analyze and diagnose = Indoor unit can not be inspected for 4 minutes continuously
Remark = resumable
Malfunction Code = 16
Trouble Description = Lack of refrigerant or discharging pipe blocked
Analyze and diagnose = If it occurs 3 times in 1 hour, confirm the failure
Remark = Non-resumable
Malfunction Code = 17
Trouble Description = 4-way vavle converse abnormal
Analyze and diagnose = If it occurs 3 times in 1 hour, confirm the failure.
Remark = Non-resumable
Malfunction Code = 18
Trouble Description = Over current in course of compressor frequency going down
Analyze and diagnose = If it occurs 3 times in 1 hour, confirm the failure, the former twice will not alarm
Remark = Non-resumable
Malfunction Code = 19
Trouble Description = Over current protection in course of compressor fixed speed operation detected by software
Analyze and diagnose = If it occurs 3 times in 1 hour, confirm the failure, the former twice will not alarm
Remark = Non-resumable
Malfunction Code = 23
Trouble Description = Module temp. too high or module temp.sensor abnormal
Analyze and diagnose = If it occurs 3 times in 1 hour, confirm the failure, the former twice will not alarm
Remark = Non-resumable
Malfunction Code = 24
Trouble Description = Over current protection in course of compressor frequency going up
down detected by software
Analyze and diagnose = If it occurs 3 times in 1 hour, confirm the failure, the former twice will not alarm
Remark = Non-resumable
Malfunction Code = 27
Trouble Description = Without connection to compressor
Analyze and diagnose = If it occurs 3 times in 1 hour, confirm the failure, the former twice will not alarm
Remark = Non-resumable
Malfunction Code = 28
Trouble Description = High voltage protection for module
Analyze and diagnose = From moudle board
Remark = resumable
Malfunction Code = 29
Trouble Description = Low voltage protection for module
Analyze and diagnose = From module board
Remark = resumable
Malfunction Code = 38
Trouble Description = Communication abnormal among modules
Analyze and diagnose = It can not detect the input signal for 2 minutes
Remark = Non-resumable
Malfunction Code = 39
Trouble Description = Mid-condenser temp. sensor abnormal
Analyze and diagnose = Sensor is detected below 20 or over 1000 for 60 seconds, but in
defrosting or within 6 minutes after defrosting, it will not alarm
Remark = resumable
Malfunction Code = 43
Trouble Description = Low pressure switch abnormal
Analyze and diagnose = After compressor running for 3 minutes, if switch is detected
unconnected for 30seconds, it alarms, if it occurs 3 times in 1 hour, confirm this failure, if it occurs 3 times in 1 hour, confirm the failure, but in defrosting or within 6 minutes after defrosting, it will not alarm
Remark = Non-resumable
Malfunction Code = 44
Trouble Description = High pressure switch abnormal
Analyze and diagnose = After compressor running for 3 minutes, if switch is detected unconnected for 30seconds, it alarms, if it occurs 3 times in 1 hour, confirm this failure, or if Tcm is over 68 degree for 10 seconds for 3 times
Remark = Non-resumable
Note: The flash times of outdoor mainboard(ECU) LED1 indicates the malfuction code. for example, LED1 flash 3 times, the malfuction code is 3.
The flash times or malfuction code of indoor unit can also indictes the malfuction code too.the method to confirm please refer to indoor unit manual
Diagnostic code for indoor unit
Flash times of Timing LED (or indoor PCB LED4)= 0
Flash times of Timing LED (or indoor PCB LED3)= 1
Failure code(from wired controller) = 01
Failure code(from panel controller) = E1
Trouble shooting = Temperature sensor Ta faulty
Possible reasons = Sensor disconected,or broken,or at wrong position, or short circuit
Flash times of Timing LED (or indoor PCB LED4)= 0
Flash times of Timing LED (or indoor PCB LED3)= 2
Failure code(from wired controller) = 02
Failure code(from panel controller) = E2
Trouble shooting = Temperature sensor Te faulty
Possible reasons = Sensor disconected,or broken,or at wrong position,or short circuit
Flash times of Timing LED (or indoor PCB LED4)= 0
Flash times of Timing LED (or indoor PCB LED3)= 4
Failure code(from wired controller) = 04
Failure code(from panel controller) =F8
Trouble shooting = EEPROM WRONG
Possible reasons = Faulty indoor unit PCB
Flash times of Timing LED (or indoor PCB LED4)= 0
Flash times of Timing LED (or indoor PCB LED3)= 7
Failure code(from wired controller) = 07
Failure code(from panel controller) = E9
Trouble shooting = Abnormalcommunication between indoor and outdoor units
Possible reasons = Wrong connection,or the wires be disconected,or wrong address setting of indoor unit,or faulty power supply or faulty PCB
Flash times of Timing LED (or indoor PCB LED4)= 0
Flash times of Timing LED (or indoor PCB LED3)= 8
Failure code(from wired controller) = NO EEROR CODE DISPLAY
Failure code(from panel controller) = E8
Trouble shooting = Abnormal communication between indoor wired controller and indoor
Possible reasons = Abnormal communication between indoor wired controller and indoor unit PCB
Flash times of Timing LED (or indoor PCB LED4)= 0
Flash times of Timing LED (or indoor PCB LED3)= 12
Failure code(from wired controller) = 0C
Failure code(from panel controller) = E0
Trouble shooting = Drainage system abnormal
Possible reasons = Pump motor disconnected,or atwrong position,or the float switch broken down,or the float switch disconected,or at wrong position.
Flash times of Timing LED (or indoor PCB LED4)= 0
Flash times of Timing LED (or indoor PCB LED3)= 13
Failure code(from wired controller) = 0D
Failure code(from panel controller) = EF
Trouble shooting = Zero cross sigal wrong
Possible reasons = Zero cross sigal detected wrong
Flash times of Timing LED (or indoor PCB LED4)= 0
Flash times of Timing LED (or indoor PCB LED3)= 14
Failure code(from wired controller) = 0E
Failure code(from panel controller) = /
Trouble shooting = Indoor unit DC fan motor abnormal
Possible reasons = DC fan motor disconnected,or DC fan motor broken,or circuit broken
Flash times of Timing LED (or indoor PCB LED4)= 0
Flash times of Timing LED (or indoor PCB LED3)= 16
Failure code(from wired controller) = 10
Failure code(from panel controller) = F3
Trouble shooting = Indoor mode abnormal
Possible reasons = Different from outdoor unit mode
Flash times of Timing LED (or indoor PCB LED4)= 2
Flash times of Timing LED (or indoor PCB LED3)= 1
Failure code(from wired controller) = 15
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 2
Flash times of Timing LED (or indoor PCB LED3)= 2
Failure code(from wired controller) = 16
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 2
Flash times of Timing LED (or indoor PCB LED3)= 4
Failure code(from wired controller) = 18
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 2
Flash times of Timing LED (or indoor PCB LED3)= 5
Failure code(from wired controller) = 19
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 2
Flash times of Timing LED (or indoor PCB LED3)= 7
Failure code(from wired controller) = 1B
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 2
Flash times of Timing LED (or indoor PCB LED3)= 8
Failure code(from wired controller) = 1C
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 2
Flash times of Timing LED (or indoor PCB LED3)= 9
Failure code(from wired controller) = 1D
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 3
Flash times of Timing LED (or indoor PCB LED3)= 0
Failure code(from wired controller) = 1F
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 3
Flash times of Timing LED (or indoor PCB LED3)= 1
Failure code(from wired controller) = 1F
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 3
Flash times of Timing LED (or indoor PCB LED3)= 2
Failure code(from wired controller) = 20
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 3
Flash times of Timing LED (or indoor PCB LED3)= 3
Failure code(from wired controller) = 21
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 3
Flash times of Timing LED (or indoor PCB LED3)= 5
Failure code(from wired controller) = 23
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 3
Flash times of Timing LED (or indoor PCB LED3)= 6
Failure code(from wired controller) = 24
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 3
Flash times of Timing LED (or indoor PCB LED3)= 7
Failure code(from wired controller) = 25
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 3
Flash times of Timing LED (or indoor PCB LED3)= 8
Failure code(from wired controller) = 26
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 3
Flash times of Timing LED (or indoor PCB LED3)= 9
Failure code(from wired controller) = 27
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 4
Flash times of Timing LED (or indoor PCB LED3)= 3
Failure code(from wired controller) = 2B
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 4
Flash times of Timing LED (or indoor PCB LED3)= 4
Failure code(from wired controller) = 2C
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons =
Flash times of Timing LED (or indoor PCB LED4)= 4
Flash times of Timing LED (or indoor PCB LED3)= 7
Failure code(from wired controller) = 2F
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 4
Flash times of Timing LED (or indoor PCB LED3)= 8
Failure code(from wired controller) = 30
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 4
Flash times of Timing LED (or indoor PCB LED3)= 9
Failure code(from wired controller) = 31
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 5
Flash times of Timing LED (or indoor PCB LED3)= 8
Failure code(from wired controller) = 3A
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 5
Flash times of Timing LED (or indoor PCB LED3)= 9
Failure code(from wired controller) = 3B
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 6
Flash times of Timing LED (or indoor PCB LED3)= 3
Failure code(from wired controller) = 3F
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
Flash times of Timing LED (or indoor PCB LED4)= 6
Flash times of Timing LED (or indoor PCB LED3)= 4
Failure code(from wired controller) = 40
Failure code(from panel controller) = /
Trouble shooting = Outdoor unit abnormal
Possible reasons = Refer to the outdoor unit troubleshooting list
1. For the indoor failure ,only running LED ON remote receiver will indicate.
2. For the outdoor failure ,timer LED and running LED will indicate.timer LED of remote receiver stands for ten's place,and running LED
stands for one's place.timer LED will flash firstly,2 seconds later,running LED will flash too. Afer that,4 seconds later,they will flash in
turns again.Flash times equals to the failure code of outdoor plus
20.For example,failure code of outdoor is 2,the indoor unit should display 22.As a result,timer LED flashes twice firstly,then running LED
flashes twice.
3.To get much more details of outdoor unit failure,Please refer to the the outdoor unit trouble shooting list
York Minisplits
Temperature Sensor Resistance Readings
Temperature = 0C
K Ohms = 35K
Temperature = 10C
K Ohms = 20K
Temperature = 20C
K Ohms = 13K
Temperature = 30C
K Ohms = 8K
Fault Codes for RAHC, YKHC & YUHC Models
Indoor lights
Operation = Flash
Timer = Flash
Defrost = Flash
Faults = Outdoor Problem
Operation =
Timer =
Defrost = Flash
Faults = ID Air Sensor Fail
Operation = Flash
Timer =
Defrost =
Faults = ID Pipe Sensor Fail
Operation =
Timer =
Defrost = Flash
Faults = OD Pipe Sensor Fail
Operation = Flash
Timer = Flash
Defrost =
Faults = PCB Fail
Outdoor LEDS 3ph models only
LED 1 = Flash
LED 2 = Off
LED 3 = Off
Faults = Phase Error
LED 1 = Flash
LED 2 = Flash
LED 3 = Off
Faults = Pressure Switch
LED 1 = Off
LED 2 = Off
LED 3 = Flash
Faults = Overcurrent
LED 1 = Off
LED 2 = Flash
LED 3 = Flash
Faults = OD Pipe Sensor
LED 1 = Off
LED 2 = Flash
LED 3 = Off
Faults = OD Air Sensor
LED 1 = Flash
LED 2 = Flash
LED 3 = Flash
Faults = Hi Temp Protection
HVHC Inverter Fault Codes
Indoor Display = E0
ID PCB Fail
Outdoor LCDs
1 = On
2 Red = Off
3 Green = Off
4 Yellow = Off
Connected to Power
Indoor Display = E1
Comms Fail
Outdoor LCDs
1 = Off
2 Red = Off
3 Green = Off
4 Yellow = Off
Power or OD PCB Fail
Indoor Display = E3
Power Abnormal
Outdoor LCDs
1 = On
2 Red = On
3 Green = Off
4 Yellow = Off
Comms Fail
Indoor Display = E4
OD Sensor Fail
Outdoor LCDs
1 = On
2 Red = Off
3 Green = Off
4 Yellow = On
Compressor Overcurrent
Indoor Display = E5
ID Sensor Fail
Outdoor LCDs
1 = On
2 Red = Off
3 Green = Flash
4 Yellow = Flash
OD Air Sensor Fail E5
Indoor Display = E6
Inverter Module
Outdoor LCDs
1 = On
2 Red = Flash
3 Green = Off
4 Yellow = Flash
OD Pipe Sensor Fail E5
Indoor Display = PO
IPM Protection
Outdoor LCDs
1 = On
2 Red = On
3 Green = Flash
4 Yellow = On
OD Power Supply P1
Indoor Display = P1
OD Power Supply
Outdoor LCDs
1 = On
2 Red = Off
3 Green = On
4 Yellow = Off
IPM Protection P0
Indoor Display = P2
Compressor Hi Temp
Outdoor LCDs
1 = On
2 Red = Off
3 Green = On
4 Yellow = On
Compressor Temp P2
Indoor Display = P3
Outdoor Low Temp
Outdoor LCDs
1 = On
2 Red = On
3 Green = Off
4 Yellow = Off
Comms E1
Indoor Display = P4
Inverter/Compressor Fail
Outdoor LCDs
1 = On
2 Red = On
3 Green = Flash
4 Yellow = Flash
Inv / Comp Fail P4
Model SM-YJCC-YJHC
Items to be checked first
1. Is the voltage of the power correct? The input voltage shall be rating voltage 10%. The air conditioner may not operate properly if the voltage is out of this range.
2. Is the link cable connecting the indoor unit and the outdoor unit linked properly? Please refer to the “wiring diagram” Check the terminals if the indoor unit and outdoor unit are properly linked by the same number of cables.
3. When a problem occurs due to the contents illustrated in the table below, it is symptom not related to themalfunction of the air conditioner.
Operation of air conditioner = In COOL operation mode, the compressor does not operate at a room temperature higher than the setting temperature that the indoor fan should operate.In a HEAT operation mode, the compressor does not operate at a room temperature lower than the setting temperature that indoor fan should operate.
Explanation = It happens after a delay of 3 minutes when the compressor is reoperated. The same phenomenon occurs when a power is on.As a phenomenon that the compressor is reoperated after adelay of 3 minutes, the indoor fan is adjusted automatically withreference to a temperature of the air blow.
Operation of air conditioner = Fan speed setting is not allowed in AUTO or DRY mode
Explanation = The speed of the indoor fan is set to low in DRY mode.Fan speed of 3 steps is selected automatically in AUTO mode.
Operation of air conditioner = Compressor stops operation intermittently in DRY mode.
Explanation = Compressor operation is automatically controlled in DRY modedepending on the room temperature and humidity.
Operation of air conditioner = Compressor of the outdoor unit is operating although it is turned off in HEAT mode.
Explanation = When the unit is turned off while de-ice is activated, thecompressor continues operation for up to 10 minutes(maximum)until the deice is completed.
Operation of air conditioner = Timer indicator lamp lights up and the air conditioner doesnot operate.
Explanation = Timer is being activated and the unit is in ready mode.The unit operates normally if the timer operation is cancelled
Operation of air conditioner = The compressor and indoor fan stop intermittently in HEATmode.
Explanation = The compressor and indoor fan stop intermittently if room temperature exceeds a setting temperature in order to protectthe compressor from overheated air in HEAT mode
Operation of air conditioner = Indoor fan and outdoor fan stop intermittently in HEAT mode.
Explanation = The compressor operates in a reverse cycle to remove exteriorice in HEAT mode, and indoor fan and outdoor fan do not operate intermittently for within 20% of the total heat operation
Operation of air conditioner = The compressor stops intermittently in COOL mode or DRYmode, and fan speed of the indoor unit decreases
Explanation = The compressor stops intermittently or the fan speed of the indoor unit decreases to prevent inside/outside air frozendepending on the inside/outside air temperature.
SELF DIAGNOSIS FUNCTION
Our company provides the end-users with thoughtful services by installing various diagnostic systems to indicate the following irregular performances
Checkcode = FAULT F6
Diagnosis of malfunction = PG motor faults
Checkcode = FAULT F7
Diagnosis of malfunction = Indoor TEMP sensor faults
Checkcode = FAULT F8
Diagnosisofmalfunction = Indoor coil pipe TEMP sensor faults
Checkcode = FAULT F9
Diagnosisofmalfunction = Outdoor coil pipe TEMP sensor faults
54 komentar:
error code A5 in york Air condition what mean?
Air Conditioning providing accurate temperature control,
and it reduce the humidity within your home to eliminate the 'stickiness' .
Most systems have a dedicated 'dry' mode,
where humidity can be reduced without over-cooling the room.
air conditionin
air conditioner
ac air conditioning
furnace
hvac
I love to be outdoors, so I like to hike, bike and go to the beach. See the link below for more info.
#outdoor
www.ufgop.org
What if e16 code.. york vrf.. how to fix it?
York mini split model HAKC-12FS-AAR operation and pre def lights flashing. Any ideas?
U2 what mean
york air con outdoor unit showing three LEDS 1,2 and 3 blinking or flashing what does this mean because the indoor is not cooling
E7 of indoor control what is the meaning of this error
Thank you
In remote display error alarm 4
YE2SD48SGCBK47 model yourk ac 10 minutes working agin indoor unit display alarm come no4 what number 4 menig
Remote display error alarm 4 ?
Can you halpe me now i have a problime ac york Erorr indoor E4
Air Con Unit display P1...What does that means?
Remote display error alarm 4?
under voltage
hello york YGGN 90000 Btu air conditioner e4 fault what is fault.
Good day,do you have error code for YMFF & YMUF Model
thanks & warm regards
Didn't see what am looking for....
outdor pc bord linght fash
Copmrasar On of
Remote display error 4?
Error codes ff, pls help
Er02
Error E5 ductsiplt unit
Model ywwh126B york ac error 22
Hi coil sensor issu
https://www.servisiz.net/klima-hata-kodlari/york-klima-hata-kodlari-cozumleri-sorun-giderme/4296
Sleep indicator flashing 2 times .,york cassette type fcu ,,help plss.
Sleep indicator flashing 2 times .,york cassette type fcu ,,same here too
York flour stand unit indoor P10 please help me
Error 88?
Indoor working but parblam e6coming indor outdoor not warking what parblam
Ec15 whats means ? York vrf system
E4 EREEAR
Hi sir I have one problem York error 51 coming alaram ,how we are sol problem
How to chak alarm 4
How to fix CF error code on midwall unit.
York VRF F3 Error.
What is problem??
York stand wall air conditioner E1 error code.
What is error code 83
P10 show on display what is problem
Alarm 5 code please
Hi sir I have a problem with a unit ducted system it showing EE on the controller and fleek 3 times on the oparation
Error code for YDOH-B-0610M(YGF)(0612)
FA error code
I also see the error code. But still not update the error code. What's the problem? You solve the problem bro?
Timer error
Timer error
Error of kuhlin F1?
OC Error code please what is it mean??please help me.
what is the mean of FE ?
A user when using this flashlight app then also entertain with SOS light, front screen white, disco light with music and strobe light option. Best app for every android phone to use the manual and auto flashlight On-off button
E10
Plz answer me E10 error
I have a York Cassette type aircon and the alarm light is flashing fast . what could be the problem and how do see what's faulty .
Post a Comment