When malfunction or protection occurs in the air coditioner, corresponding code will be displayed on the screen of the indoor unit and the indicator of outdoor unit will blink accordingly as well.
When protection or mal function is eliminated, display will be back to normal.
9, 12 MBH - 60 and 50 Hz (No LED lights on outdoor PCB)
Code = 1
Malfunction = Storage slug
Error Display
Dual 8 display = EE
Led = Heating LED-pause 3s and blink 15 times
Repair Method = Replace indoor main board
Code = 2
Malfunction = Indoor PCB malfunction
Error Display
Dual 8 display = EE
Led = Heating LED-pause 3s and blink 15 times
Repair Method = Replace indoor main board
Code = 3
Malfunction = Anti-freezing protection
Error Display
Dual 8 display = E2
Led = Running LED pause 3s and blink 2 times
Repair Method = Outdoor ambient temperature too low
Code = 4
Malfunction = Overload of system
Error Display
Dual 8 display = H4
Led = Heating LED-pause 3s and blink 4 times
Repair Method = System abnormal, check if the evaporator and codenser is dirty and blocked
Code = 5
Malfunction = No motor of indoor unit feedback
Error Display
Dual 8 display = H6
Led = Running LED-pause 3s and blink 11 times
Repair Method = Is electro motor mounted normally?
Code = 6
Malfunction = Indoor pipe temperature sensor malfunction
Error Display
Dual 8 display = F2
Led = Cooling LED-pause 3s and blink 2 times
Repair Method = Is it loose? Measure the resistant value with universal meter
Code = 7
Malfunction = Internal ambient temperature sensor malfunction
Error Display
Dual 8 display = F1
Led = Cooling LED-pause 3s and blink 1 times
Repair Method = Is it loose? Measure the resistant value with universal meter
Code = 8
Malfunction = Zero passage abnormal
Error Display
Dual 8 display = UF
Led = Heating and cooling LED blink 7 times at the same time
Repair Method = Replace indoor main board
Code = 9
Malfunction = Overload of compressor
Error Display
Dual 8 display = H3
Led = Heating LED-pause 3s and blink 3 times
Repair Method = Inspect connection state of the overload wire
Code = 10
Malfunction = Startup failure
Error Display
Dual 8 display = Lc
Led = Heating LED-pause 3s and blink 11 times
Repair Method = Check if the resistance of compressor to ground is normal, the outdoor main board may be wrong.
Code = 11
Malfunction = No motor of outdoor unit feedback
Error Display
Dual 8 display = UH
Led = Heating and cooling LED blink 8 times at the same time
Repair Method = This malfunction may happen when outdoor DC electromotor is used
Code = 12
Malfunction = Overcurrent protection
Error Display
Dual 8 display = E5
Led = Running LED-pause 3s and blink 5 times
Repair Method = Is electric network variable?
Code = 13
Malfunction = 4-way valve conversion abnormal
Error Display
Dual 8 display = U7
Led = Cooling LED-pause 3s and blink 20 times
Repair Method = Replace 4-way valve
Code = 14
Malfunction = Phase current detection malfunction of compressor
Error Display
Dual 8 display = U1
Led = Heating LED-pause 3s and blink 13 times
Repair Method = Replace outdoor mainboard
Code = 15
Malfunction = Sync failure
Error Display
Dual 8 display = H7
Led = Heating LED-pause 3s and blink 7 times
Repair Method = Check if the resistance of compressor and resistance to ground is normal, if the compressor is normal, the outdoor main board may be wrong
Code = 16
Malfunction = Current diction malfunction of complete unit
Error Display
Dual 8 display = U5
Led = Cooling LED-pause 3s and blink 13 times
Repair Method = Replace outdoor main board
Code = 17
Malfunction = Outdoor ambient temperature sensor malfunction
Error Display
Dual 8 display = F3
Led = Cooling LED-pause 3s and blink 3 times
Repair Method = Is it loose? Measure the resistance value with uiversal meter
Code = 18
Malfunction = Discharge protection of compressor
Error Display
Dual 8 display = E4
Led = Running LED-pause 3s and blink 4 times
Repair Method = Is it loose? Measure the resistance value with uiversal meter
Code = 19
Malfunction = Break-circuit and short-circuit of outdoor discharge temperature sensor
Error Display
Dual 8 display = F5
Led = Cooling LED-pause 3s and blink 5 times
Repair Method = Is it loose? Measure the resistance value with uiversal meter
Code = 20
Malfunction = Break-circuit and short-circuit of outdoor condenser temperature sensor
Error Display
Dual 8 display = F4
Led = Cooling LED-pause 3s and blink 18 times
Repair Method = Is it loose? Measure the resistance value with uiversal meter
Code = 21
Malfunction = Overheat of carbon fin
Error Display
Dual 8 display = P8
Led = Heating LED-pause 3s and blink 19 times
Repair Method = Is outdoor ambient temperature is too high? I radiator mounted correctly?
Code = 22
Malfunction = DC overcurrent
Error Display
Dual 8 display = UU
Led = Heating and cooling LED blink 11 times at the same time
Repair Method =
Code = 23
Malfunction = Temperature sensor malfunction of carbon fin
Error Display
Dual 8 display = P7
Led = Heating LED-pause 3s and blink 18 times
Repair Method = Replace outdoor main board
Code = 24
Malfunction = Lack of Freon or block protection
Error Display
Dual 8 display = F0
Led = Cooling LED-pause 3s and blink 10 times
Repair Method =
Code = 25
Malfunction = DC input voltage is too high
Error Display
Dual 8 display = PH
Led = Cooling LED-pause 3s and blink 11 times
Repair Method = Is voltage of AC power supply normal?
Code = 26
Malfunction = DC input voltage is too low
Error Display
Dual 8 display = PL
Led = Heating LED-pause 3s and blink 21 times
Repair Method = Is voltage of AC power supply normal?
Code = 27
Malfunction = Commuication malfunction
Error Display
Dual 8 display = E6
Led = Runing LED-pause 3s and blink 6 times
Repair Method = Is outdoor connecting wire reliably connected?
Code = 28
Malfunction = Setting error, indoor and outdoor unit abnormal
Error Display
Dual 8 display = UA
Led = Heating and coolig LED blink 12 times at the same time
Repair Method = Outdoor unit is not mached with indoor unit
Remarks 4min after protection stop of compressor, the malfunction is shown in error code.
In other situation, the malfunction will be displayed by press the light button for 6 times within 4s
27 komentar:
My i know what is EC error code
E3 stand for?
What is EC error code.
What EC errior code
How about L3
how about d7 trane concealed
These documents help me to an extent. A very nice explanation of HVAC working and mechanism. Heating and Cooling Oakville
This article covers a lot more updates from south Carolina.Heating and Cooling Toronto The temperatures there varies a lot.
Split duct showing EF
What is ec error code
What is EF Error code?
What is P3 error?
Our office's indoor unit display show this error.
how to solve this error.
What is ft f0 error
L1
What Err8 means?
What is er01
ec error code for the leakage indication
Error code HC in mini split Trane?
What is FE error means
What is E6 error code?
its very nice article i hope more of this topics
------
my site : شركة نظافة بالاحساء
What is 79
what is a4 code
eror bb for what
HC
Hello plz l have error code ED with a Trane ac can you help me solve it
Low freon