The tables below contain lists of error codes for several models of the Midea air conditioners. For each error code, there is a short explanation of the type of the malfunction. There are separate tables for the following series of Midea ACs: R series, 9V, 9A, and the Cassette/Ceiling&Floor series. If you’re looking for information on AC Outdoor Units, you will also nd it below.
FAULT CODE = First power on, if no address
INDICATING MEANING = The timing and operating lamps will be ashed or display FE at the
same time
FAULT CODE = M_Home not matching fault
INDICATING MEANING = 4 Lamps will be ashed or display HO at the same time
FAULT CODE = Mode conict fault
INDICATING MEANING = The defrosting lamp will be ashed or display EO
FAULT CODE = Indoor and outdoor units communication fault
INDICATING MEANING = The timing lamp will be ashed or display E1
FAULT CODE = Indoor unit temperature sensor (T1) fault
INDICATING MEANING = The operating lamp will be ashed or display E2
FAULT CODE = Swinging motor fault
INDICATING MEANING = Display E8
FAULT CODE = Temperature sensor (T2) fault
INDICATING MEANING = The operating lamp will be ashed or display E3
FAULT CODE = Temperature sensor (T2B) fault
INDICATING MEANING = The operating lamp will be ashed or display E4
FAULT CODE = EEPROM fault
INDICATING MEANING = The defrosting lamp will be ashed slowly or display E7
FAULT CODE = Outdoor unit fault
INDICATING MEANING = The alarm lamp will be ashed slowly or display Ed
FAULT CODE = Water level alarm fault
INDICATING MEANING = The alarm lamp will be ashed or display EE
Midea air conditioner error code R series
DISPLAY = E0
MALFUNCTION = EEPROM parameter error
DISPLAY = E1
MALFUNCTION = Indoor / outdoor units communication protection
DISPLAY = E2
MALFUNCTION = Zero-crossing signal error
DISPLAY = E3
MALFUNCTION = Fan speed out of control
DISPLAY = E5
MALFUNCTION = Open or short circuit of outdoor temperature sensor
DISPLAY = E6
MALFUNCTION = Open or short circuit of room or evaporator temperature sensor
DISPLAY = P0
MALFUNCTION = IGBT over-strong current protection
DISPLAY = P1
MALFUNCTION = Over voltage or too under voltage protection
DISPLAY = P2
MALFUNCTION = Temperature protection of compressor top
DISPLAY = P4
MALFUNCTION = Inverter compressor drive error
Midea air conditioner error code 9V series
* Flash (at 0.5Hz, P5 at 0.25Hz) o light x (off)
NO = 1
MALFUNCTION = EEPROM error
DEF = o
TIMER = o
AUTO = o
RUN = o
DISPLAY DIGITAL TUBE= E0
NO = 2
MALFUNCTION = Indoor / outdoor units communication protection
DEF = *
TIMER = *
AUTO = *
RUN = *
DISPLAY DIGITAL TUBE= E1
NO = 3
MALFUNCTION = Zero-crossing signal error
DEF = o
TIMER = o
AUTO = *
RUN = *
DISPLAY DIGITAL TUBE= E2
NO = 4
MALFUNCTION = Indoor fan speed out of control
DEF = o
TIMER = o
AUTO = *
RUN = *
DISPLAY DIGITAL TUBE= E3
NO = 5
MALFUNCTION = Outdoor unit temp. sensor or connector of temp. sensor is defective
DEF = x
TIMER = o
AUTO = x
RUN = *
DISPLAY DIGITAL TUBE= E5
NO = 6
MALFUNCTION = Open or short circuit of room or evaporator temperature
DEF = o
TIMER = o
AUTO = o
RUN = *
DISPLAY DIGITAL TUBE= E6
NO = 7
MALFUNCTION = Outdoor fan speed out of control
DEF = o
TIMER = o
AUTO = *
RUN = *
DISPLAY DIGITAL TUBE= E7
NO = 8
MALFUNCTION = IBM malfunction or IGBT over-strong current protection
DEF = x
TIMER = x
AUTO = o
RUN = *
DISPLAY DIGITAL TUBE= P0
NO = 9
MALFUNCTION = Over voltage or too under voltage protection
DEF = x
TIMER = o
AUTO = o
RUN = *
DISPLAY DIGITAL TUBE= P1
NO = 10
MALFUNCTION = Temperature protection of compressor top
DEF = o
TIMER = x
AUTO = x
RUN = *
DISPLAY DIGITAL TUBE= P2
NO = 11
MALFUNCTION = Compressor position protection
DEF = o
TIMER = x
AUTO = *
RUN = *
DISPLAY DIGITAL TUBE= P4
NO = 12
MALFUNCTION =
DEF = x
TIMER = o
AUTO = *
RUN = *
DISPLAY DIGITAL TUBE= P5
Midea air conditioner error code 9A series
* Flash (at 0.5Hz, P5 at 0.25Hz) o light x (off)
NO = 1
MALFUNCTION = EEPROM error
DEF = o
TIMER = o
AUTO = o
RUN = o
DISPLAY DIGITAL TUBE= E0
NO = 2
MALFUNCTION = Indoor / outdoor units communication protection
DEF = *
TIMER = *
AUTO = *
RUN = *
DISPLAY DIGITAL TUBE= E1
NO = 3
MALFUNCTION = Zero-crossing signal error
DEF = o
TIMER = o
AUTO = *
RUN = *
DISPLAY DIGITAL TUBE= E2
NO = 4
MALFUNCTION = Indoor fan speed out of control
DEF = o
TIMER = o
AUTO = *
RUN = *
DISPLAY DIGITAL TUBE= E3
NO =
MALFUNCTION =
DEF =
TIMER =
AUTO =
RUN =
DISPLAY DIGITAL TUBE=
NO = 5
MALFUNCTION = Outdoor unit temp. sensor or connector of temp. sensor is defective
DEF = x
TIMER = o
AUTO = x
RUN = *
DISPLAY DIGITAL TUBE= E5
NO = 6
MALFUNCTION = Open or short circuit of room or evaporator temperature
DEF = o
TIMER = o
AUTO = o
RUN = *
DISPLAY DIGITAL TUBE= E6
NO = 7
MALFUNCTION = Outdoor fan speed out of control
DEF = *
TIMER = o
AUTO = *
RUN = *
DISPLAY DIGITAL TUBE= E7
NO = 8
MALFUNCTION = IBM malfunction or IGBT over-strong current protection
DEF = x
TIMER = x
AUTO = o
RUN = *
DISPLAY DIGITAL TUBE= P0
NO = 9
MALFUNCTION = Over voltage or too under voltage protection
DEF = x
TIMER = o
AUTO = o
RUN = *
DISPLAY DIGITAL TUBE= P1
NO = 10
MALFUNCTION = Temperature protection of compressor top
DEF = o
TIMER = x
AUTO = x
RUN = *
DISPLAY DIGITAL TUBE= P2
NO = 11
MALFUNCTION = Compressor position protection
DEF = o
TIMER = x
AUTO = *
RUN = *
DISPLAY DIGITAL TUBE= P4
NO = 12
MALFUNCTION = Inverter module protection
DEF = x
TIMER = o
AUTO = *
RUN = *
DISPLAY DIGITAL TUBE= P5
Midea air conditioner error code Cassette/Ceiling&Floor series:
* flash, o light, x extinguished
OPERATION = *
TIMER = x
DE-FROST = x
ALARM = x
LED STATUS = Indoor room temp. sensor open or short-circuit
OPERATION = x
TIMER = x
DE-FROST = *
ALARM = x
LED STATUS = Indoor pipe temp. sensor open or short-circuit
OPERATION = x
TIMER = *
DE-FROST = x
ALARM = x
LED STATUS = Indoor and outdoor communication error
OPERATION = x
TIMER = x
DE-FROST = x
ALARM = *
LED STATUS = Water level alarm
OPERATION = *
TIMER = *
DE-FROST = x
ALARM = x
LED STATUS = EEPROM error
OPERATION = *
TIMER = x
DE-FROST = x
ALARM = o
LED STATUS = Inverter module protection
OPERATION = *
TIMER = o
DE-FROST = x
ALARM = x
LED STATUS = Outdoor sensor open or short circuit
OPERATION = *
TIMER = o
DE-FROST = x
ALARM = o
LED STATUS = Outdoor voltage protection
OPERATION = *
TIMER = x
DE-FROST = o
ALARM = x
LED STATUS = Compressor top temp. protection
OPERATION = *
TIMER = x
DE-FROST = o
ALARM = o
LED STATUS = Mode conict
OPERATION = *
TIMER = x
DE-FROST = *
ALARM = *
LED STATUS = Outdoor current protection
Midea AC Outdoor Units error code (except M5OA-36HRDN1-Q model)
DISPLAY = E0
LED STATUS = EEPROM error
DISPLAY = E1
LED STATUS = No A Indoor unit coil outlet temp. sensor or connector of sensor is defective
DISPLAY = E2
LED STATUS = No B Indoor unit coil outlet temp. sensor or connector of sensor is defective
DISPLAY = E3
LED STATUS = No C Indoor unit coil outlet temp. sensor or connector of sensor is defective
DISPLAY = E6
LED STATUS = No D Indoor unit coil outlet temp. sensor or connector of sensor is defective
DISPLAY = E4
LED STATUS = Outdoor unit temp. sensor or connector of temp. sensor is defective
DISPLAY = E5
LED STATUS = Compressor voltage protection
DISPLAY = E7
LED STATUS = Communication malfunction between outdoor main chip and compressor control chip
DISPLAY = P0
LED STATUS = Temperature protection of compressor discharge or compressor top.
For M4OC-36HRDN1-Q,it only means compressor discharge temp.protection.
DISPLAY = P1
LED STATUS = High pressure protection(only for M4OC1-27HRDN1-Q, M4OC-36HRDN1-Q)
DISPLAY = P2
LED STATUS = Low pressure protection(only for M4OC1-27HRDN1-Q, M4OC-36HRDN1-Q)
DISPLAY = P3
LED STATUS = Compressor current protection
DISPLAY = P4
LED STATUS = Inverter module protection
DISPLAY = P6
LED STATUS = Condenser high-temperature protection
Midea AC Outdoor Units error code For M5OA-36HRDN1-Q model
DISPLAY = E0
LED STATUS = EEPROM error
DISPLAY = E1
LED STATUS = No A Indoor unit coil outlet temp. sensor or connector of sensor is defective
DISPLAY = E2
LED STATUS = Communication malfunction between outdoor unit and indoor units
DISPLAY = E3
LED STATUS = Communication malfunction between outdoor main chip and compressor control chip
DISPLAY = E4
LED STATUS = Outdoor unit temp. sensor or connector of temp. sensor is defective
DISPLAY = E5
LED STATUS = Compressor voltage protection
DISPLAY = E6
LED STATUS = PFC module protection
DISPLAY = P0
LED STATUS = Compressor top. temperature protection
DISPLAY = P1
LED STATUS = High pressure protection
DISPLAY = P2
LED STATUS = Low pressure protection
DISPLAY = P3
LED STATUS = Compressor current protection
DISPLAY = P4
LED STATUS = Compressor discharge high-temperature protection
DISPLAY = P5
LED STATUS = Condenser high-temperature protection
DISPLAY = P6
LED STATUS = Inverter module protection
DISPLAY = F1
LED STATUS = No A Indoor unit coil outlet temp. sensor or connector of sensor is defective
DISPLAY = F2
LED STATUS = No B Indoor unit coil outlet temp. sensor or connector of sensor is defective
DISPLAY = F3
LED STATUS = No C Indoor unit coil outlet temp. sensor or connector of sensor is defective
DISPLAY = F4
LED STATUS = No D Indoor unit coil outlet temp. sensor or connector of sensor is defective
DISPLAY = F5
LED STATUS = No E Indoor unit coil outlet temp. sensor or connector of sensor is defective
Midea MSH-21HRN1-QB8 air conditioner error code
FAILURE PHENOMENON = Over current protection of the compressor occurs 4 times
OPERATION LAMP = ☆
TIMER LAMP = ☆
DEFROSTING LAMP = ☆
AUTO LAMP = ☆
FAILURE PHENOMENON = Indoor room temp, sensor is open circuit or short circuit
OPERATION LAMP = X
TIMER LAMP = ☆
DEFROSTING LAMP = X
AUTO LAMP = X
FAILURE PHENOMENON = Temp, sensor on indoor evaporator is open circuit or short circuit
OPERATION LAMP = ☆
TIMER LAMP = X
DEFROSTING LAMP = X
AUTO LAMP = X
FAILURE PHENOMENON = Temp, sensor on outdoor condenser is open circuit or short circuit
(without cooling only models)
OPERATION LAMP = X
TIMER LAMP = X
DEFROSTING LAMP = ☆
AUTO LAMP = X
FAILURE PHENOMENON = Outdoor unit protects (outdoor compressor current, phase order etc)
OPERATION LAMP = X
TIMER LAMP = X
DEFROSTING LAMP =
AUTO LAMP =
FAILURE PHENOMENON = EEROM error
OPERATION LAMP =X
TIMER LAMP = ☆
DEFROSTING LAMP = X
AUTO LAMP = ☆
FAILURE PHENOMENON = Indoor unit communication error
OPERATION LAMP = X
TIMER LAMP = X
DEFROSTING LAMP = X
AUTO LAMP = ☆
Midea MSC-09HRDN1-QD0(E) air conditioner error code
0-Bright
×-Extinguished
☆- Blink
MALFUNCTION = Over voltage or too low voltage protection
LED6 (GREEN) = 0
LED5 (RED) = 0
INDOOR DISPLAY = P1
MALFUNCTION = Normal standby
LED6 (GREEN) = 0
LED5 (RED) = X
INDOOR DISPLAY =
MALFUNCTION = MCE malfunction
LED6 (GREEN) = 0
LED5 (RED) = ☆
INDOOR DISPLAY = P1
MALFUNCTION = Normal operation
LED6 (GREEN) = 0
LED5 (RED) = 0
INDOOR DISPLAY =
MALFUNCTION = MCE start malfunction
LED6 (GREEN) = X
LED5 (RED) = ☆
INDOOR DISPLAY = P4
MALFUNCTION = MCE phase lack protection, MCE zero speed protection, PWM in-phase
malfunction
LED6 (GREEN) = ☆
LED5 (RED) = 0
INDOOR DISPLAY = P4
MALFUNCTION = IGBT over-strong current
LED6 (GREEN) = ☆
LED5 (RED) = X
INDOOR DISPLAY = PO
MALFUNCTION = Communication malfunction
LED6 (GREEN) = ☆
LED5 (RED) = ☆
INDOOR DISPLAY = P4
Midea M2OC-18HRDN1-M air conditioner error code
DISPLAY = EO
LED STATUS = EEPROM parameter error
DISPLAY = E1
LED STATUS = No 1 Indoor units pipe temp, sensor or connector of pipe temp, sensor is defective
DISPLAY = E2
LED STATUS = No 2 Indoor units pipe temp, sensor or connector of pipe temp, sensor is defective
DISPLAY = E3
LED STATUS = No 3 Indoor units pipe temp, sensor or connector of pipe temp, sensor is defective
DISPLAY = E6
LED STATUS = No 4 Indoor units pipe temp, sensor or connector of pipe temp, sensor is defective
DISPLAY = E4
LED STATUS = Open or short circuit of outdoor temperature sensor
DISPLAY = E5
LED STATUS = Compressor volt protection
DISPLAY = E7
LED STATUS = Communication error between outdoor IC and DSP
DISPLAY = PO
LED STATUS = Temperature protection of compressor top.
DISPLAY = P1
LED STATUS = High pressure protection (just for 36K 1x4 units.)
DISPLAY = P2
LED STATUS = Low pressure protection (just for 36K 1x4 units.)
DISPLAY = P3
LED STATUS = Compressor current protection
DISPLAY = P4
LED STATUS = Inverter module protection
DISPLAY = P5
LED STATUS = Outdoor temp, too low protection
DISPLAY = P6
LED STATUS = Condenser high-temperature protection
DISPLAY = P7
LED STATUS = Compressor driving protection
DISPLAY = PF
LED STATUS = PFC protection (just for 36K 1x4 units.)
Midea MSX-07HRN1-QC2 air conditioner error code
LED = E1
FAILURE = EEPROM error
LED = E2
FAILURE = Zero crossing detection error
LED = E3
FAILURE = Indoor fan speed has been out of control
LED = E4
FAILURE = Over current protection occurs 4 times
LED = E5
FAILURE = The T1 sensor is open circuit or short circuit
LED = E6
FAILURE = The T2 sensor is open circuit or short circuit
LED = E7
FAILURE = The T3 sensor is open circuit or short circuit
LED = E9
FAILURE = Indoor / outdoor units communication error
Midea MSMBB-12CRDN1-MP0W air conditioner error code
O-(light) X-(off) ☆- (flash)
OPERATION LAMP = ☆ 1 time
TIMER LAMP = X
DISPLAY = EO
LED STATUS = Indoor unit EEPROM parameter error
OPERATION LAMP = ☆ 2 times
TIMER LAMP = X
DISPLAY = E1
LED STATUS = Indoor / outdoor units communication error
OPERATION LAMP = ☆ 3 times
TIMER LAMP = X
DISPLAY = E2
LED STATUS = Zero-crossing signal detection error
OPERATION LAMP = ☆ 4 times
TIMER LAMP = X
DISPLAY = E3
LED STATUS = Indoor fan speed has been out of control
OPERATION LAMP = ☆ 5 times
TIMER LAMP = X
DISPLAY = E4
LED STATUS = Indoor room temperature sensor T1 open circuit or short circuit
OPERATION LAMP = ☆ 6 times
TIMER LAMP = X
DISPLAY = E5
LED STATUS = Evaporator coil temperature sensor T2 open circuit or short circuit
OPERATION LAMP = ☆ 7 times
TIMER LAMP = X
DISPLAY = EC
LED STATUS = Refrigerant leakage detection
OPERATION LAMP = ☆ 1 times
TIMER LAMP = 0
DISPLAY = FO
LED STATUS = Overload current protection
OPERATION LAMP = ☆ 2 times
TIMER LAMP = 0
DISPLAY = F1
LED STATUS = Outdoor ambient temperature sensor T4 open circuit or short circuit
OPERATION LAMP = ☆ 3 times
TIMER LAMP = 0
DISPLAY = F2
LED STATUS = Condenser coil temperature sensor T3 open circuit or short circuit
OPERATION LAMP = ☆ 4 times
TIMER LAMP = 0
DISPLAY = F3
LED STATUS = Compressor discharge temperature sensor T5 open circuit or short circuit
OPERATION LAMP = ☆ 5 times
TIMER LAMP = 0
DISPLAY = F4
LED STATUS = Outdoor unit EEPROM parameter error
OPERATION LAMP = ☆ 6 times
TIMER LAMP = 0
DISPLAY = F5
LED STATUS = Outdoor fan speed has been out of control
OPERATION LAMP = ☆ 1 times
TIMER LAMP = ☆
DISPLAY = PO
LED STATUS = IPM malfunction or IGBT over-strong current protection
OPERATION LAMP = ☆ 2 times
TIMER LAMP = ☆
DISPLAY = P1
LED STATUS = Over voltage or over low voltage protection
OPERATION LAMP = ☆ 3 times
TIMER LAMP = ☆
DISPLAY = P2
LED STATUS = High temperature protection of compressor top diagnosis and solution
OPERATION LAMP = ☆ 5 times
TIMER LAMP = ☆
DISPLAY = P4
LED STATUS = Inverter compressor drive error
Part1. Outdoor Error Code Explanation
Display = E1
Malfunction or Protection = Phase Protection
Display = E2
Malfunction or Protection = Communication error between indoor units and outdoor unit
Display = E3
Malfunction or Protection = Outdoor tube temperature sensor T3 malfunction
Display = E4
Malfunction or Protection = Outdoor ambient temperature sensor T4 malfunction
Display = E5
Malfunction or Protection = Digital discharge temperature sensor T5 malfunction
Display = E6
Malfunction or Protection = Outdoor tube temperature sensor T3B malfunction
Display = E9
Malfunction or Protection = Voltage error
Display = H1
Malfunction or Protection = Communication malfunction between chips
Display = H2
Malfunction or Protection = Quantity of MS lessen (recovered by cut off the power)
Display = P1
Malfunction or Protection = Hi-pressure protection
Display = P2
Malfunction or Protection = Low-pressure protection
Display = P3
Malfunction or Protection = Digital compressor current protection
Display = P4
Malfunction or Protection = Digital compressor discharge temperature protection
Display = P5
Malfunction or Protection = Outdoor condenser high temperature protection
Display = P7
Malfunction or Protection = Current protection, No.1 fixed compressor
Display = dF
Malfunction or Protection = Defrosting
MSC-18HRIN1; MSH-18HRIN1
MSE-09HRIN2; MSE-12HRIN2
Indoor Unit Error Display
Display LED STATUS
E0 EEPROM error
E1 Indoor / outdoor units communication protection
E2 Zero-crossing examination error
E3 Fan speed beyond control
E5 Open or short circuit of outdoor temperature sensor
E6 Room temperature or evaporator temperature sensor open or short circuit of
P0 Module protection
P1 Over voltage or too low voltage protection
P2 Compressor top protection against temperature
P3 Outdoor low temp. protection
P4 Inverter compressor drive error
31 komentar:
So with operation and defrost blinking continuously on indoor unit, it would be error e6 right? Its midea msg09hrn1.
Thanks
Hello ,my midea has an error code P0 what is the cause and how can i fix it....please!Thanks.
Error code E24?
my midea mga-f30w/s show "EC" in lcd (interior unit) and "E2" in display of motherboard (exterior unit). help please!
E3 how
If indoor unit showing E3 it means fan speed beyond the control . Most probably electronic control board will be a faulty
Midea aircon model CR002 RG05D4 202055090978 showing an E1 on panel how do i fix it
We error code what can cause it and solution?
Error code EE .
Midea Type MGFA-48ARN1 show in display P11.
Could you suggestion me, how to fix it?
So what component would be likely to cause a E9 fault. Unit model is MSK24M3 split system
So what component would be likely to cause a E9 fault. Unit model is MSK24M3 split system
hi the device display p7 how to fix it
Mine, the error code is E3 the technician come with new outdoor fan motor. The problem still not settle.
P12
EC led display in room air conditioner. What's happening?
hello , I have P7 error on mfj36CR model. what is the problem?
hello,i have midea mission model 12 btu which work perfect but
after 1 hour it stops and bleeping 88 can some one help me pls tks
hello I have a problem I have split air condition Midea MSR-24HR model (R6) she works on heating after a while we phenomenon on the screen red light and that's when the # symbol of this electricity is poor me a 180 volt air conditioner is operating at 220 whether it is a problem ?
P10 error on MFJ-36CR . What is the problem
P12
Hi my midea coming with e1
E3 error mfj48 arn1
nice post.Modular kitchen in chennai
Modular kitchen chennai
P11 errors
Gas Problem
H1 error so May Ac
I have an code: _ _
I can't find anything about it everywhere.
Error code FE???
FE error code in midea aircon multi split??
My midea cassette Inverter 2.5 HP show in display F7. Please can you help me out