Wednesday, December 29, 2021

Koppel Air Conditioner Error Codes


Indoor unit malfunction For floor standing
 
Indoor EEPROM malfunction E0 
Communication malfunction between indoor and outdoor units E1 
Open or short circuit of T1 temperature sensor E4 
Open or short circuit of T2 temperature sensor E5 
Refrigerant leakage detection EC 
Outdoor unit is faulty (for old communication protocol) Ed 
Overcurrent protection (For some units) F0 
Open or short circuit of T4 temperature sensor F1 
Open or short circuit of T3 temperature sensor F2 
Open or short circuit of T5 temperature sensor F3 
Outdoor EEPROM malfunction (For some units) F4 
Open or short circuit of T2B temperature sensor F6 
IPM module malfunction P0 
Over voltage or over low voltage protection P1 
High temperature protection of top of compressor P2 
Too low ambient temperature protection P3 
Inverter compressor drive protection P4 
Sensor of outdoor IGBT is faulty P7

For Other Type

O (on) X(off) ☆(flash)

Malfunction = Indoor EEPROM malfunction
Error Code = E0
Timer Lamp = X
Operation Lamp ( Flashes ) = 1

Malfunction = Communication malfunction between indoor and outdoor units
Error Code = E1
Timer Lamp = X
Operation Lamp ( Flashes ) = 2

Malfunction = Open or short circuit of T1 temperature sensor
Error Code = E4
Timer Lamp = X
Operation Lamp ( Flashes ) = 5

Malfunction = Open or short circuit of T2 temperature sensor
Error Code = E5
Timer Lamp = X
Operation Lamp ( Flashes ) = 6

Malfunction = Refrigerant leakage detection
Error Code = EC
Timer Lamp = X
Operation Lamp ( Flashes ) = 7

Malfunction = Water level alarm
Error Code = EE
Timer Lamp = X
Operation Lamp ( Flashes ) = 8

Malfunction = Communication error between master and slave unit (for twins system)
Error Code = E8
Timer Lamp = X
Operation Lamp ( Flashes ) = 9

Malfunction = Another indoor unit malfunction (for twins system)
Error Code = E9
Timer Lamp = X
Operation Lamp ( Flashes ) = 10

Malfunction = Outdoor unit is faulty (for old communication protocol)
Error Code = Ed
Timer Lamp = X
Operation Lamp ( Flashes ) = 11

Malfunction = Overcurrent protection (For some units)
Error Code = F0
Timer Lamp = O
Operation Lamp ( Flashes ) = 1

Malfunction = Open or short circuit of T4 temperature sensor
Error Code = F1
Timer Lamp = O
Operation Lamp ( Flashes ) = 2

Malfunction = Open or short circuit of T3 temperature sensor
Error Code = F2
Timer Lamp = O
Operation Lamp ( Flashes ) = 3

Malfunction = Open or short circuit of T5 temperature sensor
Error Code = F3
Timer Lamp = O
Operation Lamp ( Flashes ) = 4

Malfunction = Outdoor EEPROM malfunction (For some units)
Error Code = F4
Timer Lamp = O
Operation Lamp ( Flashes ) = 5

Malfunction = Communication error between auto-lifting panel and slim cassette (For slim cassette with auto-lifting panel)
Error Code = F7
Timer Lamp = O
Operation Lamp ( Flashes ) = 8

Malfunction = Auto-lifting panel is faulty (For slim cassette with auto-lifting panel) 
Error Code = F8
Timer Lamp = O
Operation Lamp ( Flashes ) = 9

Malfunction = Auto-lifting panel is not closed (For slim cassette with auto-lifting panel)
Error Code = F9
Timer Lamp = O
Operation Lamp ( Flashes ) = 10

Malfunction = IPM module malfunction
Error Code = P0
Timer Lamp = ☆
Operation Lamp ( Flashes ) = 1

Malfunction = Over voltage or over low voltage protection
Error Code = P1
Timer Lamp = ☆
Operation Lamp ( Flashes ) = 2

Malfunction = High temperature protection of top of compressor
Error Code = P2
Timer Lamp = ☆
Operation Lamp ( Flashes ) = 3

Malfunction = Too low ambient temperature protection
Error Code = P3
Timer Lamp = ☆
Operation Lamp ( Flashes ) = 4

Malfunction = Inverter compressor drive protection
Error Code = P4
Timer Lamp = ☆
Operation Lamp ( Flashes ) = 5

Malfunction = Low pressure protection of compressor
Error Code = P6
Timer Lamp = ☆
Operation Lamp ( Flashes ) = 7

Malfunction = Sensor of outdoor IGBT is faulty
Error Code = P7
Timer Lamp = ☆
Operation Lamp ( Flashes ) = 8


Outdoor Unit Malfunction

E1 Communication malfunction between indoor and outdoor units
F0 Overcurrent protection
F1 Ambient temperature sensor (T4) is malfunction
F2 Outdoor heat-exchanger temperature sensor (T3) is malfunction
F3 Discharge temperature sensor (T5) is malfunction
F4 Outdoor EEPROM is malfunction
P0 IPM module protection
P1 Voltage protection (too high or too low)
P3 Protection of ultra-low ambient temperature
P4 Rotor position protection of compressor
J0 High temperature protection of indoor heat exchanger in heating mode
J1 High temperature protection of outdoor heat exchanger in cooling mode
J2 High discharge temperature protection
J3 PFC module protection
J4 Communication error between outdoor main chip and compressor driven chip IR341
J5 High pressure protection
J6 Low pressure protection
P7 Sensor of outdoor IGBT is faulty
J8 AC voltage protection

In low ambient cooling mode, the LED displays“LC” or alternative displays between running frequency
and “LC”(each displays 0.5s)




Kindly Bookmark this Post using your favorite Bookmarking service:
Technorati Digg This Stumble Stumble Facebook Twitter

1 komentar:

surecool on December 29, 2021 at 6:42 PM said...

this blog content was really well thanks for sharing blogspot
By
surecool aircon singapore


aircon service
aircon servicing
best aircon service
aircon servicing singapore


Enquire Book now 65 86538092

Post a Comment

 

| List of fault or error codes air conditioners © 2014. All Rights Reserved | Template Style by My Blogger Tricks .com | Design by Brian Gardner | Back To Top |