Friday, December 31, 2021

Gree Ducted GFH Error Codes


 Error Code = E1

Malfunction Name = High Pressure Protection

Origin Of Malfunction Signal = High pressure switch . 

Control Description = When outdoor unit detects the high pressure switch is cut off for 3s successively, high pressure protection will occur. All the loads (except the 4-way valve in heating mode) will be switched off. In this case, all the buttons and remote control signals except ON/OFF button will be disabled and cannot be recovered automatically. Switch off the unit or re-energize the unit after cutting off power to eliminate this protection. 


Error Code = E2

Malfunction Name = Freeze protection 

Origin Of Malfunction Signal = Indoor evaporator temperature sensor 

Control Description = If detecting that the evaporator temperature is lower than protective temp. value after the unit has been running for a period of time under cooling or dry mode, the unit will report this fault, in which case the compressor and outdoor fan motor will be stopped. The unit will not run until evaporator temperature is higher than the protective temp. value and the compressor is stopped for 3min 


Error Code = E3

Malfunction Name = Refrigerant lacking protection 

Origin Of Malfunction Signal =

Control Description = If the unit reports system refrigerant lacking within 10min after turning on the unit, the unit will stop operation. If the fault occurs successively 3 times, the unit cannot be recovered automatically. 

Error Code = E3

Malfunction Name = Refrigerant recycling mode 

Origin Of Malfunction Signal =

Control Description = If enter refrigerant recycling mode through special operation, E3 will be displayed. After exiting refrigerant recycling mode, the code will disappear


Error Code = E4

Malfunction Name = Compressor high discharge temperature protection 

Origin Of Malfunction Signal = Compressor discharge temperature is high 

Control Description = If outdoor unit detects that the discharge temperature is higher than protective temp. value, the unit will report high discharge temperature protection. If the protection occurs over 6 times, the unit cannot be recovered automatically. Switch off the unit or re-energize the unit after cutting off power to eliminate this protection. 


Error Code = E6

Malfunction Name = Communication malfunction 

Origin Of Malfunction Signal = Communication between indoor and outdoor mainboard 

Control Description = If the outdoor unit does not receive data from indoor unit, communication malfunction will be reported. If there is communication abnormity between display board and indoor unit, communication malfunction will be reported too


Error Code = E8

Malfunction Name = Malfunction of indoor fan motor 

Origin Of Malfunction Signal = Indoor fan motor 

Control Description = If the indoor unit does not receive signal from indoor fan motor for 30s successively when the fan motor is operating, indoor fan motor malfunction will be reported. In this case, the unit can automatically resume operation after stopping. If the malfunction occurs 6 times within one hour, the unit cannot be recovered automatically. Switch off the unit or re-energize the unit after cutting off power to eliminate this malfunction


Error Code = E9

Malfunction Name = Full water protection 

Origin Of Malfunction Signal = Water level switch 

Control Description = If cut-off of water level switch is detected for 8s successively once energized, the system will enter full water protection. In this case, switch off the unit and then switch it on to eliminate this malfunction


Error Code = F0

Malfunction Name = Malfunction of indoor ambient temperature sensor at air return port

Origin Of Malfunction Signal = Indoor ambient temperature sensor 

Control Description = If the indoor ambient temperature sensor is detected of open circuit or short circuit for 5s successively, indoor ambient temperature sensor malfunction will be reported. The unit can automatically resume operation after the malfunction disappears. If indoor ambient temperature sensor malfunction occurs in fan mode, only the error code is displayed and the indoor unit can work normally. 


Error Code = F1

Malfunction Name = Malfunction of evaporator temperature sensor 

Origin Of Malfunction Signal = Evaporator temperature sensor 

Control Description = If the indoor evaporator temperature sensor is detected of open circuit or short circuit for 5s successively, evaporator temperature sensor malfunction will be reported. The unit can automatically resume operation after the malfunction disappears. If evaporator temperature sensor malfunction occurs in fan mode, only the error code is displayed and the indoor unit can work normally. 


Error Code = F2

Malfunction Name = Malfunction of condenser temperature sensor 

Origin Of Malfunction Signal = Condenser temperature sensor 

Control Description = If the outdoor condenser temperature sensor is detected of open circuit or short circuit for 5s successively, condenser temperature sensor malfunction will be reported. The unit can automatically resume operation after the malfunction disappears. If condenser temperature sensor malfunction occurs in fan mode, only the error code is displayed and the indoor unit can work normally


Error Code = F3

Malfunction Name = Malfunction of outdoor ambient temperature sensor 

Origin Of Malfunction Signal = Outdoor ambient temperature sensor 

Control Description = If the outdoor ambient temperature sensor is detected of open circuit or short circuit for 5s successively, outdoor ambient temperature sensor malfunction will be reported. The unit can automatically resume operation after the malfunction disappears. If outdoor ambient temperature sensor malfunction occurs in fan mode, only the error code is displayed and the indoor unit can work normally. 


Error Code = F4

Malfunction Name = Malfunction of discharge temperature sensor 

Origin Of Malfunction Signal = Discharge temperature sensor 

Control Description = If the outdoor ambient temperature sensor is detected of open circuit or short circuit for 5s successively, outdoor ambient temperature sensor malfunction will be reported. The unit can automatically resume operation after the malfunction disappears. If outdoor ambient temperature sensor malfunction occurs in fan mode, only the error code is displayed and the indoor unit can work normally. 


Error Code = F5

Malfunction Name = Malfunction wired controller temperature sensor 

Origin Of Malfunction Signal = Wired controller 

Control Description = If the wired controller detects open circuit or short circuit of its temperature sensor for 5s successively, wired controller temperature sensor malfunction will be reported 


Error Code = ee

Malfunction Name = Malfunction of outdoor drive memory chip 

Origin Of Malfunction Signal = Outdoor drive board 

Control Description = If the memory chip of outdoor drive board is broken, the unit cannot be started. The unit cannot be recovered automatically. If the malfunction cannot be eliminated after switching off the unit and then energizing the unit for several times, please replace the outdoor drive board. 


Error Code = H3

Malfunction Name = Compressor overload protection 

Origin Of Malfunction Signal = Compressor overload switch 

Control Description = If it is detected within 3s successively that the overload switch is cut off under ON or standby state, the unit will report overload protection. If the fault occurs successively 3 times, the unit cannot be recovered automatically. Switch off the unit or re-energize the unit after cutting off power to eliminate this protection 


Error Code = H4

Malfunction Name = Overload protection 

Origin Of Malfunction Signal = Evaporator temperature, condenser temperature 

Control Description = If outdoor unit detects that the tube temperature is higher than protective temp. value, the unit will report overload protection. The unit will not restart operation until tube temperature is lower than the protective temp. value and the compressor is stopped for 3min. If the protection occurs over 6 times, the unit cannot be recovered automatically. Switch off the unit or re-energize the unit after cutting off power to eliminate this protection. 


Error Code = H6

Malfunction Name = Malfunction of outdoor fan motor 

Origin Of Malfunction Signal = Outdoor fan motor 

Control Description = If the outdoor unit does not receive signal from outdoor fan motor for 30s successively when the fan motor is operating, outdoor fan motor malfunction will be reported. In this case, the unit can automatically resume operation after stopping. If the malfunction occurs 6 times within one hour, the unit cannot be recovered automatically. Switch off the unit or re-energize the unit after cutting off power to eliminate this malfunction


Error Code = U7

Malfunction Name = Direction changing malfunction of 4-way valve 

Origin Of Malfunction Signal = 4-way valve 

Control Description = After the compressor starts operation in heating mode, if the outdoor unit detects the difference between evaporator temperature and indoor ambient temperature is lower than the protective value for 10min successively, direction changing malfunction of 4-way valve will be reported and the outdoor unit will stop operation. The unit can automatically resume operation in the first two malfunctions. If the malfunction occurs 3 times, the unit cannot be recovered automatically. Switch off the unit or re-energize the unit after cutting off power to eliminate this malfunction


Error Code = P6

Malfunction Name = Communication malfunction between main control and drive 

Origin Of Malfunction Signal = Communication between main control board and drive board 

Control Description = If the outdoor main control board does not receive data from drive board, communication malfunction between main control and drive will be reported. This malfunction can be eliminated automatically


Error Code = EE

Malfunction Name = Malfunction of outdoor main control memory chip 

Origin Of Malfunction Signal = Outdoor main control board 

Control Description = If the memory chip of outdoor main control board is broken, the unit cannot be started. The unit cannot be recovered automatically. If the malfunction cannot be eliminated after switching off the unit and then energizing the unit for several times, please replace the outdoor main control board 


Description of Drive Malfunction 

Main board dual 8 numeral tube Display Codes for Outdoor Unit of 24~60k 


Malfunction Item = DC busbar over-voltage protection 

Indoor Unit Display = PH

Outdoor unit display of dual 8 numeral tube  = PH


Malfunction Item =  IPM or PFC over-temperature protection 

Indoor Unit Display = P8

Outdoor unit display of dual 8 numeral tube  = P8


Malfunction Item = Current sense circuit error 

Indoor Unit Display = Pc

Outdoor unit display of dual 8 numeral tube  = Pc


Malfunction Item = IPM or PFC temperature sensor error 

Indoor Unit Display = P7

Outdoor unit display of dual 8 numeral tube  = P7


Malfunction Item = Compressor current protection 

Indoor Unit Display = P5

Outdoor unit display of dual 8 numeral tube  = P5


Malfunction Item = DC busbar under-voltage protection 

Indoor Unit Display = PL

Outdoor unit display of dual 8 numeral tube  = PL


Malfunction Item = Compressor startup failure 

Indoor Unit Display = Lc

Outdoor unit display of dual 8 numeral tube  = Lc


Malfunction Item = Drive module reset 

Indoor Unit Display = P0

Outdoor unit display of dual 8 numeral tube  = P0


Malfunction Item = Compressor motor desynchronizing 

Indoor Unit Display = H7

Outdoor unit display of dual 8 numeral tube  = H7


Malfunction Item = Phase loss 

Indoor Unit Display = Ld

Outdoor unit display of dual 8 numeral tube  = Ld


Malfunction Item = Drive-to-main-control communication error 

Indoor Unit Display = P6

Outdoor unit display of dual 8 numeral tube  = P6


Malfunction Item = IPM protection

Indoor Unit Display = H5

Outdoor unit display of dual 8 numeral tube  = H5


Malfunction Item = Compressor overload protection 

Indoor Unit Display = H3

Outdoor unit display of dual 8 numeral tube  = H3


Malfunction Item = AC current protection (input side

Indoor Unit Display = PA

Outdoor unit display of dual 8 numeral tube  = PA


Malfunction Item = Charging circuit error 

Indoor Unit Display = PU

Outdoor unit display of dual 8 numeral tube  = PU


Malfunction Item = PFC protection 

Indoor Unit Display = HC

Outdoor unit display of dual 8 numeral tube  = HC


Malfunction Item = DC fan error 

Indoor Unit Display = H6

Outdoor unit display of dual 8 numeral tube  = H6


Malfunction Item = Input AC voltage abnormality 

Indoor Unit Display = PP

Outdoor unit display of dual 8 numeral tube  = PP


Malfunction Item = Driving board memory chip error 

Indoor Unit Display = ee

Outdoor unit display of dual 8 numeral tube  = ee



Kindly Bookmark this Post using your favorite Bookmarking service:
Technorati Digg This Stumble Stumble Facebook Twitter

26 komentar:

Mr Maintenance Services on March 2, 2022 at 3:06 PM said...

What a fantastic post. This is chock full of useful information. I reach a lot of blog posts and I never heard of a topic like this.
Washing machine repairing services in Islamabad

Aaaaccounting on July 25, 2022 at 11:25 AM said...

Hello! I came throughout your web site by way of . I really hope you continue to write good articles. Many thanks.
Accounting service in London

TheBEGlobal on August 5, 2022 at 7:02 PM said...

Thanks for Sharing. BEglobal is one of the leading SEO Company in Dubai. We deal with every SEO challenge to encourage your online visibility.

BEGlobal(US)LLC on August 30, 2022 at 3:39 PM said...

Thanks for sharing. We provide SEM Services in Michigan at a reasonable price. It can help grow your revenue.

Trendingtales on September 8, 2022 at 2:20 PM said...

Hi like your blog very much thank for sharing it. Everything we know about The Greatest Beer Run Ever

Trendingtales on September 8, 2022 at 2:21 PM said...

What You Should Know About Medieval Film (2022)

Trendingtales on September 15, 2022 at 6:31 PM said...

Know about Shawana Nakesia Chapman Bio, Husband, and net worth

bloging on September 16, 2022 at 1:34 PM said...

hy

bloging on September 16, 2022 at 1:38 PM said...

Nice Blog, keep it up for more information like this. Visit our page
Wallpaper in Canada

bloging on September 16, 2022 at 1:39 PM said...

Thanks for Information: Dry Erase Wallpaper

Trendingtales on October 3, 2022 at 6:02 PM said...

Release information, cast, and narrative for Glass Onion: A Knives Out Mystery

Duniyakamood on October 3, 2022 at 6:43 PM said...

घर के मुख्य द्वार पर मां लक्ष्मी के चरण चिह्न लगाने से मिलते है कई लाभ, परंतु जान लें ये विशेष बातें!

Arslan Kulachi on October 4, 2022 at 1:59 PM said...

Thanks for sharing best portable car air conditioner

Trendingtales on October 7, 2022 at 6:38 PM said...

TILL RELEASE DATE, CAST, PLOT, REVIEW (2022)

Duniyakamood on October 10, 2022 at 6:43 PM said...

नहीं रहे नेता जी शोक में डूबा देश, प्रधानमंत्री समेत बड़े नेताओं ने कुछ इस तरह दी श्रद्धांजलि

Arslan Kulachi on October 13, 2022 at 12:26 PM said...

That's amazing content. I would like to tell you about my blog best portable car air conditioner

Arslan Kulachi on October 14, 2022 at 1:02 PM said...

Love to read it . I would like to tell you about my blog home theatre power manager

Trendingtales on October 20, 2022 at 6:07 PM said...

THE LIMITED SERIES FROM SCRATCH IS COMING TO NETFLIX, STARRING ZOE SALDANA.

Duniyakamood on October 20, 2022 at 7:43 PM said...

ब्लैक एडम रिव्यु: ब्लैक एडम के किरदार में ड्वेन ने डाली जान

Trendingtales on October 31, 2022 at 5:07 PM said...

Everything You Should Know About the Film Spirited (2022)

Trendingtales on November 4, 2022 at 4:28 PM said...

An Advent Story Christmas: Information About The HBO Max Movie's Release Date

Duniyakamood on November 8, 2022 at 7:44 PM said...

सलमान खान की फिल्म टाइगर 3 में नजर आएंगे शाहरुख खान; पठान रिलीज होने के बाद करेंगे शूटिंग

BEGlobal(US)LLC on November 17, 2022 at 4:20 PM said...

Thanks for sharing. BEglobalus is one of leading Web Development Company in Los Angeles. Our knowledgeable team is passionate about design patterns, simple user interfaces, and efficient customer engagement. We have years of experience.

Duniyakamood on November 22, 2022 at 7:20 PM said...

इस दिन रिलीज होगा चिरंजीवी, रवि तेजा और श्रुति हासन स्टारर वाल्टेयर वीरय्या का टीज़र

CLADING2222 on June 20, 2023 at 7:15 PM said...

تفوم شركات تركيب شيش الحماية بالتركيب على الأسطح المعرضة للتسربات والتسربات المائية، مثل أسطح الأبنية والمنازل والمستودعات والمصانع. يتم تثبيتها بشكل جيد باستخدام مسامير أو غراء قوي لضمان عدم حدوث تسربات في المستقبل.

hammadpasha on September 26, 2023 at 11:07 PM said...

Kenwood AC 1838 is best ac

Post a Comment

 

| List of fault or error codes air conditioners © 2014. All Rights Reserved | Template Style by My Blogger Tricks .com | Design by Brian Gardner | Back To Top |