Thursday, June 16, 2011

GREE Wall Mounted and Ducted Error Codes


GREE Ducted Air-conditioning Error Codes

Error code = E1
error = Compressor high pressure cutout (beep)

Error code = E2
error = Indoor coil freeze protection

Error code = E3
error = Compressor low pressure cut out (beep)

Error code = F0
error = Indoor room temperature failure

Error code = F1
error = Indoor coil temperature failure

Error code = F2
error = outdoor ambient temperature failure

Error code = F3
error = outdoor coil temperature failure

GREE Split air conditioners Error Code

Name of malfunction = Refrigerant system high pressure protection
Display of double eight code = E1
Display of lamp
Running lamp = blink 1 time
Cooling lamp =
Heating lamp =

Name of malfunction = Anti-freezing protection
Display of double eight code = E2
Display of lamp
Running lamp = blink 2 times
Cooling lamp =
Heating lamp =

Name of malfunction = Compressor exhaust high temperature protection
Display of double eight code = E4
Display of lamp
Running lamp = blink 4 times
Cooling lamp =
Heating lamp =

Name of malfunction = AC over-current protection
Display of double eight code = E5
Display of lamp
Running lamp = blink 5 times
Cooling lamp =
Heating lamp =

Name of malfunction = Communication failure between indoor unit and outdoor unit
Display of double eight code = E6
Display of lamp
Running lamp = blink 6 times
Cooling lamp =
Heating lamp =

Name of malfunction =Anti-high temperature protection
Display of double eight code = E8
Display of lamp
Running lamp = blink 8 times
Cooling lamp =
Heating lamp =

Name of malfunction = No feedback of indoor fan motor
Display of double eight code = H6
Display of lamp
Running lamp = blink 11 times
Cooling lamp =
Heating lamp =

Name of malfunction = Jumper cap malfunction protection
Display of double eight code = C5
Display of lamp
Running lamp = blink 15 times
Cooling lamp =
Heating lamp =

Name of malfunction = Indoor ambient sensor open or short circuit
Display of double eight code = F1
Display of lamp
Running lamp =
Cooling lamp = blink 1 times
Heating lamp =

Name of malfunction = Indoor tube sensor open or short circuit
Display of double eight code = F2
Display of lamp
Running lamp =
Cooling lamp = blink 2 times
Heating lamp =

Name of malfunction = Outdoor ambient sensor open or short circuit
Display of double eight code = F3
Display of lamp
Running lamp =
Cooling lamp = blink 3 times
Heating lamp =

Name of malfunction = Outdoor tube sensor open or short circuit
Display of double eight code = F4
Display of lamp
Running lamp =
Cooling lamp = blink 4 times
Heating lamp =

Name of malfunction = Exhaust sensor open or short circuit
Display of double eight code = F5
Display of lamp
Running lamp =
Cooling lamp = blink 5 times
Heating lamp =

Name of malfunction = Over load limit/drop frequency
Display of double eight code = F6
Display of lamp
Running lamp =
Cooling lamp = Blink 6 times
Heating lamp =

Name of malfunction = Over current limit/drop frequency
Display of double eight code = F8
Display of lamp
Running lamp =
Cooling lamp = blink 8 times
Heating lamp =

Name of malfunction = High exhaust temperature limit/drop frequency
Display of double eight code = F9
Display of lamp
Running lamp =
Cooling lamp = blink 9 times
Heating lamp =

Name of malfunction = Over voltage protection for PN
Display of double eight code = PH
Display of lamp
Running lamp =
Cooling lamp = blink 11 times
Heating lamp =

Name of malfunction = AC current detect circuit malfunction
Display of double eight code = U5
Display of lamp
Running lamp =
Cooling lamp = blink 13 times
Heating lamp =

Name of malfunction = Compressor reverse protection
Display of double eight code = U4
Display of lamp
Running lamp = 
Cooling lamp = blink 14 times
Heating lamp =

Name of malfunction = Over compressor phase current protection
Display of double eight code = P5
Display of lamp
Running lamp =
Cooling lamp = blink 15 times
Heating lamp =

Name of malfunction = Inlet tube sensor malfucntion
Display of double eight code = b5
Display of lamp
Running lamp =
Cooling lamp = blink 19 times
Heating lamp =

Name of malfunction = Outdoor DC fan motor malfunction
Display of double eight code = L3
Display of lamp
Running lamp =
Cooling lamp = blink 21 times
Heating lamp =

Name of malfunction = Outlet tube sensor malfunction
Display of double eight code = b7
Display of lamp
Running lamp =
Cooling lamp = blink 22 times
Heating lamp =

Name of malfunction = Compressor overload sensor malfunction 
Display of double eight code = FE
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =

Name of malfunction = Defrosting
Display of double eight code = H1
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 1 time

Name of malfunction = Static clearing dust protection
Display of double eight code = H2
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 2 times

Name of malfunction = Compressor overload protection
Display of double eight code = H3
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 3 times

Name of malfunction = System abnormal protection
Display of double eight code = H4
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 4 times

Name of malfunction = IPM protection
Display of double eight code = H5
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 5 times

Name of malfunction = PFC protection
Display of double eight code = HC
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 6 times

Name of malfunction = Compressor loss step protection
Display of double eight code = H7
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 7 times

Name of malfunction = Heating anti-high temperature drop frequency
Display of double eight code = HO
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 10 times

Name of malfunction = Start-up failure
Display of double eight code = Lc
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 11 times

Name of malfunction = Compressor protection against loss of phase
Display of double eight code = U2
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 12 times

Name of malfunction = Compressor phase current detection circuit malfunction
Display of double eight code = U1
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 13 times

Name of malfunction = Compressor demagnetization protection 
Display of double eight code = HE
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 14 times

Name of malfunction = Loading EEPROM malfunction
Display of double eight code = EE
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 15 times

Name of malfunction = Communication failure between main board and driver board
Display of double eight code = P6
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 16 times

Name of malfunction = Capasitor charge malfunction
Display of double eight code = PU
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 17 times

Name of malfunction = IPM sensor circuit malfunction
Display of double eight code = P7
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 18 times

Name of malfunction = IPM high temperature protection
Display of double eight code = P8
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 19 times

Name of malfunction = PN voltage drop protection
Display of double eight code = U3
Display of lamp
Running lamp =
Cooling lamp = blink 20 times
Heating lamp =

Name of malfunction = Low PN voltage protection
Display of double eight code = PL
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 21 times

Name of malfunction = Current detect circuit malfunction or current sensor malfunction
Display of double eight code = Pc
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =

Name of malfunction = Compressor loss of phase protection
Display of double eight code = Ld
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =

Name of malfunction = Compressor or locked rotary protection
Display of double eight code = LE
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =

Name of malfunction = IPM over temperature limit/drop frequency
Display of double eight code = EU
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =

Name of malfunction =  4-way valve reversal abnormal
Display of double eight code = U7
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =

Name of malfunction = Disconnection of the exhaust temperature sensor
Display of double eight code = U8
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =

Name of malfunction = AC power zero voltage detect error
Display of double eight code = U9
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =

Name of malfunction = Over tube temperature drop frequency
Display of double eight code = FA
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =

Name of malfunction = Anti-freezing limit/drop frequency
Display of double eight code = FH
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =

Kindly Bookmark this Post using your favorite Bookmarking service:
Technorati Digg This Stumble Stumble Facebook Twitter

21 komentar:

funner on December 22, 2012 at 3:17 PM said...

what a nice blog here,,
can u help me to solve these problem?

error U8, H6, and F1...
how to solve these probelms..

please send me an email,,,

jason.wijaya38@yahoo.com

Unknown on June 7, 2013 at 6:46 PM said...

you have display many error code but it may be different to every one so why is this discussion.
ducted airconditioning toowoomba

Unknown on June 30, 2016 at 7:21 AM said...

What about p11I don't have any information about it

Unknown on July 19, 2016 at 4:04 AM said...

Need help on solving H6 error

Unknown on August 18, 2016 at 1:25 PM said...

H5 eror code solution

Unknown on August 30, 2016 at 6:39 AM said...

I need F0 error code solution

Unknown on October 27, 2016 at 2:25 PM said...

H6 is indoor blower moter error replace the pg sensor or moter

Unknown on April 22, 2017 at 4:45 PM said...

Greeting could you explain eroor E04
Please

Unknown on June 3, 2017 at 12:26 AM said...

I m facing U9 error code when my generator on.please advice me .

Unknown on March 17, 2018 at 8:56 PM said...

Adnan Sahb plz adjust your Genrator frequency 52 hz

Unknown on April 1, 2018 at 2:52 AM said...

I am getting U5 error on my gree inverter ... please some body help to resolve the issue.

TheOne on April 21, 2018 at 9:53 PM said...

Asalaam
my gree (inverter) indoor unit showing U9 error all of a sudden
i had shut it down to avoid any uunforeseen damage.
can you please let me know?

thanks
Tufail

Unknown on May 12, 2018 at 2:27 PM said...

U5error a raja ha plz help

Unknown on May 13, 2018 at 3:54 PM said...

E04

Unknown on May 18, 2018 at 3:49 AM said...

H1

Unknown on May 30, 2018 at 6:11 PM said...

Kindly help me to resolve H4 error

Unknown on June 21, 2019 at 9:05 PM said...

Same as me

Unknown on August 21, 2019 at 2:28 AM said...

I need FO error code solutions

Victoria Martinez on September 2, 2019 at 6:00 PM said...

Shutting down the AC unit before cleaning and maintenance always helps out. Nice tips given above. Heating and Cooling Woodbridge

Unknown on April 25, 2020 at 12:52 AM said...

P13

Unknown on July 5, 2021 at 12:09 AM said...

Blue Star error codes pu and pL what's problem

Post a Comment

 

| List of fault or error codes air conditioners © 2014. All Rights Reserved | Template Style by My Blogger Tricks .com | Design by Brian Gardner | Back To Top |