GREE Ducted Air-conditioning Error Codes
Error code = E1
error = Compressor high pressure cutout (beep)
Error code = E2
error = Indoor coil freeze protection
Error code = E3
error = Compressor low pressure cut out (beep)
Error code = F0
error = Indoor room temperature failure
Error code = F1
error = Indoor coil temperature failure
Error code = F2
error = outdoor ambient temperature failure
Error code = F3
error = outdoor coil temperature failure
GREE Split air conditioners Error Code
Name of malfunction = Refrigerant system high pressure protection
Display of double eight code = E1
Display of lamp
Running lamp = blink 1 time
Cooling lamp =
Heating lamp =
Name of malfunction = Anti-freezing protection
Display of double eight code = E2
Display of lamp
Running lamp = blink 2 times
Cooling lamp =
Heating lamp =
Name of malfunction = Compressor exhaust high temperature protection
Display of double eight code = E4
Display of lamp
Running lamp = blink 4 times
Cooling lamp =
Heating lamp =
Name of malfunction = AC over-current protection
Display of double eight code = E5
Display of lamp
Running lamp = blink 5 times
Cooling lamp =
Heating lamp =
Name of malfunction = Communication failure between indoor unit and outdoor unit
Display of double eight code = E6
Display of lamp
Running lamp = blink 6 times
Cooling lamp =
Heating lamp =
Name of malfunction =Anti-high temperature protection
Display of double eight code = E8
Display of lamp
Running lamp = blink 8 times
Cooling lamp =
Heating lamp =
Name of malfunction = No feedback of indoor fan motor
Display of double eight code = H6
Display of lamp
Running lamp = blink 11 times
Cooling lamp =
Heating lamp =
Name of malfunction = Jumper cap malfunction protection
Display of double eight code = C5
Display of lamp
Running lamp = blink 15 times
Cooling lamp =
Heating lamp =
Name of malfunction = Indoor ambient sensor open or short circuit
Display of double eight code = F1
Display of lamp
Running lamp =
Cooling lamp = blink 1 times
Heating lamp =
Name of malfunction = Indoor tube sensor open or short circuit
Display of double eight code = F2
Display of lamp
Running lamp =
Cooling lamp = blink 2 times
Heating lamp =
Name of malfunction = Outdoor ambient sensor open or short circuit
Display of double eight code = F3
Display of lamp
Running lamp =
Cooling lamp = blink 3 times
Heating lamp =
Name of malfunction = Outdoor tube sensor open or short circuit
Display of double eight code = F4
Display of lamp
Running lamp =
Cooling lamp = blink 4 times
Heating lamp =
Name of malfunction = Exhaust sensor open or short circuit
Display of double eight code = F5
Display of lamp
Running lamp =
Cooling lamp = blink 5 times
Heating lamp =
Name of malfunction = Over load limit/drop frequency
Display of double eight code = F6
Display of lamp
Running lamp =
Cooling lamp = Blink 6 times
Heating lamp =
Name of malfunction = Over current limit/drop frequency
Display of double eight code = F8
Display of lamp
Running lamp =
Cooling lamp = blink 8 times
Heating lamp =
Name of malfunction = High exhaust temperature limit/drop frequency
Display of double eight code = F9
Display of lamp
Running lamp =
Cooling lamp = blink 9 times
Heating lamp =
Name of malfunction = Over voltage protection for PN
Display of double eight code = PH
Display of lamp
Running lamp =
Cooling lamp = blink 11 times
Heating lamp =
Name of malfunction = AC current detect circuit malfunction
Display of double eight code = U5
Display of lamp
Running lamp =
Cooling lamp = blink 13 times
Heating lamp =
Name of malfunction = Compressor reverse protection
Display of double eight code = U4
Display of lamp
Running lamp =
Cooling lamp = blink 14 times
Heating lamp =
Name of malfunction = Over compressor phase current protection
Display of double eight code = P5
Display of lamp
Running lamp =
Cooling lamp = blink 15 times
Heating lamp =
Name of malfunction = Inlet tube sensor malfucntion
Display of double eight code = b5
Display of lamp
Running lamp =
Cooling lamp = blink 19 times
Heating lamp =
Name of malfunction = Outdoor DC fan motor malfunction
Display of double eight code = L3
Display of lamp
Running lamp =
Cooling lamp = blink 21 times
Heating lamp =
Name of malfunction = Outlet tube sensor malfunction
Display of double eight code = b7
Display of lamp
Running lamp =
Cooling lamp = blink 22 times
Heating lamp =
Name of malfunction = Compressor overload sensor malfunction
Display of double eight code = FE
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =
Name of malfunction = Defrosting
Display of double eight code = H1
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 1 time
Name of malfunction = Static clearing dust protection
Display of double eight code = H2
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 2 times
Name of malfunction = Compressor overload protection
Display of double eight code = H3
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 3 times
Name of malfunction = System abnormal protection
Display of double eight code = H4
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 4 times
Name of malfunction = IPM protection
Display of double eight code = H5
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 5 times
Name of malfunction = PFC protection
Display of double eight code = HC
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 6 times
Name of malfunction = Compressor loss step protection
Display of double eight code = H7
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 7 times
Name of malfunction = Heating anti-high temperature drop frequency
Display of double eight code = HO
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 10 times
Name of malfunction = Start-up failure
Display of double eight code = Lc
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 11 times
Name of malfunction = Compressor protection against loss of phase
Display of double eight code = U2
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 12 times
Name of malfunction = Compressor phase current detection circuit malfunction
Display of double eight code = U1
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 13 times
Name of malfunction = Compressor demagnetization protection
Display of double eight code = HE
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 14 times
Name of malfunction = Loading EEPROM malfunction
Display of double eight code = EE
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 15 times
Name of malfunction = Communication failure between main board and driver board
Display of double eight code = P6
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 16 times
Name of malfunction = Capasitor charge malfunction
Display of double eight code = PU
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 17 times
Name of malfunction = IPM sensor circuit malfunction
Display of double eight code = P7
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 18 times
Name of malfunction = IPM high temperature protection
Display of double eight code = P8
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 19 times
Name of malfunction = PN voltage drop protection
Display of double eight code = U3
Display of lamp
Running lamp =
Cooling lamp = blink 20 times
Heating lamp =
Name of malfunction = Low PN voltage protection
Display of double eight code = PL
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 21 times
Name of malfunction = Current detect circuit malfunction or current sensor malfunction
Display of double eight code = Pc
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =
Name of malfunction = Compressor loss of phase protection
Display of double eight code = Ld
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =
Name of malfunction = Compressor or locked rotary protection
Display of double eight code = LE
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =
Name of malfunction = IPM over temperature limit/drop frequency
Display of double eight code = EU
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =
Name of malfunction = 4-way valve reversal abnormal
Display of double eight code = U7
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =
Name of malfunction = Disconnection of the exhaust temperature sensor
Display of double eight code = U8
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =
Name of malfunction = AC power zero voltage detect error
Display of double eight code = U9
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =
Name of malfunction = Over tube temperature drop frequency
Display of double eight code = FA
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =
Name of malfunction = Anti-freezing limit/drop frequency
Display of double eight code = FH
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =
21 komentar:
what a nice blog here,,
can u help me to solve these problem?
error U8, H6, and F1...
how to solve these probelms..
please send me an email,,,
jason.wijaya38@yahoo.com
you have display many error code but it may be different to every one so why is this discussion.
ducted airconditioning toowoomba
What about p11I don't have any information about it
Need help on solving H6 error
H5 eror code solution
I need F0 error code solution
H6 is indoor blower moter error replace the pg sensor or moter
Greeting could you explain eroor E04
Please
I m facing U9 error code when my generator on.please advice me .
Adnan Sahb plz adjust your Genrator frequency 52 hz
I am getting U5 error on my gree inverter ... please some body help to resolve the issue.
Asalaam
my gree (inverter) indoor unit showing U9 error all of a sudden
i had shut it down to avoid any uunforeseen damage.
can you please let me know?
thanks
Tufail
U5error a raja ha plz help
E04
H1
Kindly help me to resolve H4 error
Same as me
I need FO error code solutions
Shutting down the AC unit before cleaning and maintenance always helps out. Nice tips given above. Heating and Cooling Woodbridge
P13
Blue Star error codes pu and pL what's problem