While the indoor unit monitors the operation status of the air conditioner, if the protective circuit operates, the contents of self-diagnosis are displayed with block on the indoor unit indication section.

Item = A
Check code =
Block display = OPERATION (GREEN) Flashing display (1 Hz)
Description for self-diagnosis = Power failure (When power is ON)

Item = B
Check code = 00
Block display = OPERATION (Green) Flashing display (5 Hz)
Description for self-diagnosis = Protective circuit operation for indoor P.C board

Item = C
Check code = 01
Block display = OPERATION (green) TIMER (Yellow) Flashing display (5 Hz)
Description for self-diagnosis = Protective circuit operation for connecting cable and signal system.

Item = D
Check code = 02
Block display = Operation (green) filter (orange)
Description for self-diagnosis = Protective circuit operation for outdoor P.C board

Item = E
Check code = 03
Block display = OPERATION (green) TIMER (Yellow) Flashing display (5 Hz)
Description for self-diagnosis = Protective circuit operation for others (including compressor)


Caution at Servicing
1. After servicing, press the START/STOP button to return to the normal mode.
2. After servicing by the check code, turn off breaker of the supply and turn on breaker of the power supply again so that memory in the microcomputer returns the initial status.
however, the check codes are not deleted even if the power supply is turned off because they are stored in the fixed memory.
3 After servicing, press (CLR) button under check mode status and then send the check code "7F" to the indoor unit.
The error code stored in memory is cleared.

Block distinction
Check code = 00
Block = Indoor P.C. board etc
operation of diagnosis function
Check code = 0C
Cause of operation = Short-circuit or disconnection of the room temperature sensor (TA sensor)
Air conditioner status = Operation continues
Remark = Diplayed when error is detected.
Judgment and action = 1. Check tje room temp sensor
2. When the room temp sensor is normal, check P.C. board

Block distinction
Check code = 00
Block = Indoor P.C. board etc
operation of diagnosis function
Check code = 0d
Cause of operation = Being out of place, disconnection, short circuit or migration of heat exchanger sensor (TC sensor)
Air conditioner status = Operation continues
Remark = Diplayed when error is detected
Judgment and action = 1. Check heat exchanger sensor
2. when heat exchanger sensor is normal, check P.C board

Block distinction
Check code = 00
Block = Indoor P.C. board etc
operation of diagnosis function
Check code = 11
Cause of operation = Lock of indoor fan or trouble on indoor fan circuit
Air conditioner status = All off
Remark = Diplayed when error is detected
Judgment and action = 1. Check the motor
2. When the motor is normal, check P.C board

Block distinction
Check code = 00
Block = Not displayed
operation of diagnosis function
Check code = 12
Cause of operation = Trouble on other indoor P.C board
Air conditioner status = Operation continues
Remark = Diplayed when error is detected
Judgment and action = Replace P.C board

Block distinction
Check code = 01
Block = Connecting cable and serial signal
operation of diagnosis function
Check code = 04
Cause of operation = Return serial signal is not sent to indoor side from operation started
1. Defective wiring of connecting cable.
2. Operation of compressor thermo gas shortage gas leak
Air conditioner status = Operation continues
Remark = Flashes when trouble is detected on Return serial signal, and normal status when signal is reset.
Judgment and action = 1. When the outdoor unit never operate:
- Check connecting cable and connect if defective wiring.
- Check 25A fuse of inverter P.C board
- Check 3.15 A of inverter P.C board
2. To display (Other) block during operation, check compressor thermo.
Operation and supply gas (check gas leak also)
3. Unit operates normally during check.
if rreturn serial signal does not stop between indoor terminal board 2 and 3, replace inverter P.C board.
if signal stops between indoor terminal board 2 and 3, replace indoor P.C board.

Block distinction
Check code = 02
Block = Outdoor P.C board
operation of diagnosis function
Check code = 14
Cause of operation = Inverter over-current protective circuit operates. (Short time)
Air conditioner status =All off
Remark = Displayed when error is detected.
Judgment and action = Event if trying operation again, all operations stop immediately : Replace P.C board.

Block distinction
Check code = 02
Block = Outdoor P.C board
operation of diagnosis function
Check code = 16
Cause of operation = Position-detect circuit error or short circuit between windings of compressor
Air conditioner status = All off
Remark = Displayed when error is detected.
Judgment and action = 1. Even if connecting lead wire of compressor is removed, position-detect circuit error occured : Replace P.C board.
2. Measure resistance between of compressor, and perform short circuit : Replace compressor.

Block distinction
Check code = 02
Block = Outdoor P.C board
operation of diagnosis function
Check code = 17
Cause of operation = Current-detect circuit error
Air conditioner status = All off
Remark = Displayed when error is detected
Judgment and action = Event if trying operation again, all opperation stp immediately : Replace P.C board.

Block distinction
Check code = 02
Block = Outdoor P.C board
operation of diagnosis function
Check code = 18
Cause of operation = Being of place, disconnection or short circuit of the outdoor heat exchanger sensor (TE) or suction temp sensor (Ts)
Air conditioner status = All off
Remark = Displayed when error is detected
Judgment and action = 1. Check sensor (TE and TS) 2. Check P.C board.

Block distinction
Check code = 02
Block = Outdoor P.C board
operation of diagnosis function
Check code = 19
Cause of operation = Disconection or short circuit of the discharge temp sensor
Air conditioner status = All off
Remark = Displayed when error is detected
Judgment and action = 1. Check discharge temp sensor (TD) 2. Check P.C board

Block distinction
Check code = 02
Block = Outdoor P.C board
operation of diagnosis function
Check code = 1A
Cause of operation = Outdoor fan drive system error
Air conditioner status = All off
Remark = Displayed when error is detected
Judgment and action = Position-detect error, over-current protective operation of outdoor fan drive system, fan lock or etc.
Replace P.C board or fan motor.

Block distinction
Check code = 02
Block = Not displayed
operation of diagnosis function
Check code = 1b
Cause of operation = Outdoor heat exchanger temp sensor error
Air conditioner status = Operation continues
Remark =
Judgment and action = 1. Check outdoor temp sensor (TO) 2. Check P.C board

Block distinction
Check code = 02
Block = Outdoor P.C board
operation of diagnosis function
Check code = 1C
Cause of operation = Compressor drive output error, compressor error (lock, missing or etc), Break down
Air conditioner status = All off
Remark = Displayed when error is detected
Judgment and action = When 20 seconds passed after start-up, position-detect circuit error occured : replace compressor or trouble on P.M.V.

Block distinction
Check code = 03
Block = Others (including compressor)
operation of diagnosis function
Check code = 07
Cause of operation = Return serial signal has been sent when peration started, but it is not sent from halfway.
Air conditioner status = Operation continues
Remark = Flashes when trouble is detected on return serial signal, and normal status when signal is reset.
Judgment and action = 1. Repeat start an stop with interval of approx 10 to 40 minutes (Code is not displated during operation)
supply gas (Check also gas leak)
2. Unit operates normally during check.
if return serial signal does not stop between indoor terminal block 2 and 3 replace inverter P.C board.
if signal stops between indoor terminal block 2 and 3, replace indoor P.C board.

Block distinction
Check code = 03
Block = Others (including compressor)
operation of diagnosis function
Check code = 1d
Cause of operation = Compressor does not rotate. (Current protective circuit does not operate when a spceified time passed after compressor had been activated).
Air conditioner status = All off
Remark = Displayed when error is detected
Judgment and action = 1. Trouble on compressor 2. Trouble on wiring of compressor (missed phase)

Block distinction
Check code = 03
Block = Others (including compressor)
operation of diagnosis function
Check code = 1E
Cause of operation = Discharge temp exceeded 117 degrees
Air conditioner status = All off
Remark = Displayed when error is detected
Judgment and action = 1. Check discharge temp sensor (TD) 2. Gas leakage. 3. Trouble on P.M.V

Block distinction
Check code = 03
Block = Others (including compressor)
operation of diagnosis function
Check code = 1F
Cause of operation = Break down compressor
Air conditioner status = All off
Remark = Displayed when error is detected
Judgment and action = 1. Check power voltage (220-230-240 V + 10%) 2. Overload operation of refrigeration cycle. check installation condition (Short-circuit of outdoor diffuser)

Block distinction
Check code = 03
Block = Others (including compressor)
operation of diagnosis function
Check code = 08
Cause of operation = 4-way valve inverse error (TC sensor value lowered during heating operation)
Air conditioner status = Operation continues
Remark =
Judgment and action = 1. Check 4-way valve operation
Kindly Bookmark this Post using your favorite Bookmarking service:
Technorati Digg This Stumble Stumble Facebook Twitter

5 komentar:

Unknown on June 23, 2018 at 5:29 PM said...

Thanks for more information

Unknown on November 29, 2020 at 6:16 PM said...

Xpower gold error 112

Unknown on May 26, 2021 at 6:53 AM said...

7F error?

Yhamz05 on June 4, 2021 at 8:19 AM said...

error code 16

Unknown on December 16, 2021 at 6:45 PM said...

Error 12?

Post a Comment

 

| List of fault or error codes air conditioners © 2014. All Rights Reserved | Template Style by My Blogger Tricks .com | Design by Brian Gardner | Back To Top |