GREE Ducted Air-conditioning Error Codes
Error code = E1
error = Compressor high pressure cutout (beep)
Error code = E2
error = Indoor coil freeze protection
Error code = E3
error = Compressor low pressure cut out (beep)
Error code = F0
error = Indoor room temperature failure
Error code = F1
error = Indoor coil temperature failure
Error code = F2
error = outdoor ambient temperature failure
Error code = F3
error = outdoor coil temperature failure
GREE Split air conditioners Error Code
Name of malfunction = Refrigerant system high pressure protection
Display of double eight code = E1
Display of lamp
Running lamp = blink 1 time
Cooling lamp =
Heating lamp =
Name of malfunction = Anti-freezing protection
Display of double eight code = E2
Display of lamp
Running lamp = blink 2 times
Cooling lamp =
Heating lamp =
Name of malfunction = Compressor exhaust high temperature protection
Display of double eight code = E4
Display of lamp
Running lamp = blink 4 times
Cooling lamp =
Heating lamp =
Name of malfunction = AC over-current protection
Display of double eight code = E5
Display of lamp
Running lamp = blink 5 times
Cooling lamp =
Heating lamp =
Name of malfunction = Communication failure between indoor unit and outdoor unit
Display of double eight code = E6
Display of lamp
Running lamp = blink 6 times
Cooling lamp =
Heating lamp =
Name of malfunction =Anti-high temperature protection
Display of double eight code = E8
Display of lamp
Running lamp = blink 8 times
Cooling lamp =
Heating lamp =
Name of malfunction = No feedback of indoor fan motor
Display of double eight code = H6
Display of lamp
Running lamp = blink 11 times
Cooling lamp =
Heating lamp =
Name of malfunction = Jumper cap malfunction protection
Display of double eight code = C5
Display of lamp
Running lamp = blink 15 times
Cooling lamp =
Heating lamp =
Name of malfunction = Indoor ambient sensor open or short circuit
Display of double eight code = F1
Display of lamp
Running lamp =
Cooling lamp = blink 1 times
Heating lamp =
Name of malfunction = Indoor tube sensor open or short circuit
Display of double eight code = F2
Display of lamp
Running lamp =
Cooling lamp = blink 2 times
Heating lamp =
Name of malfunction = Outdoor ambient sensor open or short circuit
Display of double eight code = F3
Display of lamp
Running lamp =
Cooling lamp = blink 3 times
Heating lamp =
Name of malfunction = Outdoor tube sensor open or short circuit
Display of double eight code = F4
Display of lamp
Running lamp =
Cooling lamp = blink 4 times
Heating lamp =
Name of malfunction = Exhaust sensor open or short circuit
Display of double eight code = F5
Display of lamp
Running lamp =
Cooling lamp = blink 5 times
Heating lamp =
Name of malfunction = Over load limit/drop frequency
Display of double eight code = F6
Display of lamp
Running lamp =
Cooling lamp = Blink 6 times
Heating lamp =
Name of malfunction = Over current limit/drop frequency
Display of double eight code = F8
Display of lamp
Running lamp =
Cooling lamp = blink 8 times
Heating lamp =
Name of malfunction = High exhaust temperature limit/drop frequency
Display of double eight code = F9
Display of lamp
Running lamp =
Cooling lamp = blink 9 times
Heating lamp =
Name of malfunction = Over voltage protection for PN
Display of double eight code = PH
Display of lamp
Running lamp =
Cooling lamp = blink 11 times
Heating lamp =
Name of malfunction = AC current detect circuit malfunction
Display of double eight code = U5
Display of lamp
Running lamp =
Cooling lamp = blink 13 times
Heating lamp =
Name of malfunction = Compressor reverse protection
Display of double eight code = U4
Display of lamp
Running lamp =
Cooling lamp = blink 14 times
Heating lamp =
Name of malfunction = Over compressor phase current protection
Display of double eight code = P5
Display of lamp
Running lamp =
Cooling lamp = blink 15 times
Heating lamp =
Name of malfunction = Inlet tube sensor malfucntion
Display of double eight code = b5
Display of lamp
Running lamp =
Cooling lamp = blink 19 times
Heating lamp =
Name of malfunction = Outdoor DC fan motor malfunction
Display of double eight code = L3
Display of lamp
Running lamp =
Cooling lamp = blink 21 times
Heating lamp =
Name of malfunction = Outlet tube sensor malfunction
Display of double eight code = b7
Display of lamp
Running lamp =
Cooling lamp = blink 22 times
Heating lamp =
Name of malfunction = Compressor overload sensor malfunction
Display of double eight code = FE
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =
Name of malfunction = Defrosting
Display of double eight code = H1
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 1 time
Name of malfunction = Static clearing dust protection
Display of double eight code = H2
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 2 times
Name of malfunction = Compressor overload protection
Display of double eight code = H3
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 3 times
Name of malfunction = System abnormal protection
Display of double eight code = H4
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 4 times
Name of malfunction = IPM protection
Display of double eight code = H5
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 5 times
Name of malfunction = PFC protection
Display of double eight code = HC
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 6 times
Name of malfunction = Compressor loss step protection
Display of double eight code = H7
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 7 times
Name of malfunction = Heating anti-high temperature drop frequency
Display of double eight code = HO
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 10 times
Name of malfunction = Start-up failure
Display of double eight code = Lc
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 11 times
Name of malfunction = Compressor protection against loss of phase
Display of double eight code = U2
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 12 times
Name of malfunction = Compressor phase current detection circuit malfunction
Display of double eight code = U1
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 13 times
Name of malfunction = Compressor demagnetization protection
Display of double eight code = HE
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 14 times
Name of malfunction = Loading EEPROM malfunction
Display of double eight code = EE
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 15 times
Name of malfunction = Communication failure between main board and driver board
Display of double eight code = P6
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 16 times
Name of malfunction = Capasitor charge malfunction
Display of double eight code = PU
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 17 times
Name of malfunction = IPM sensor circuit malfunction
Display of double eight code = P7
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 18 times
Name of malfunction = IPM high temperature protection
Display of double eight code = P8
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 19 times
Name of malfunction = PN voltage drop protection
Display of double eight code = U3
Display of lamp
Running lamp =
Cooling lamp = blink 20 times
Heating lamp =
Name of malfunction = Low PN voltage protection
Display of double eight code = PL
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp = blink 21 times
Name of malfunction = Current detect circuit malfunction or current sensor malfunction
Display of double eight code = Pc
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =
Name of malfunction = Compressor loss of phase protection
Display of double eight code = Ld
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =
Name of malfunction = Compressor or locked rotary protection
Display of double eight code = LE
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =
Name of malfunction = IPM over temperature limit/drop frequency
Display of double eight code = EU
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =
Name of malfunction = 4-way valve reversal abnormal
Display of double eight code = U7
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =
Name of malfunction = Disconnection of the exhaust temperature sensor
Display of double eight code = U8
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =
Name of malfunction = AC power zero voltage detect error
Display of double eight code = U9
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =
Name of malfunction = Over tube temperature drop frequency
Display of double eight code = FA
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =
Name of malfunction = Anti-freezing limit/drop frequency
Display of double eight code = FH
Display of lamp
Running lamp =
Cooling lamp =
Heating lamp =
Read More ->>