- When protection display is available, controller will show error code, digital LED shows
error code and setting temperature by turns.
- If there is more than one failure, it will show at first that in front of the error list.
- Protection display function can be selected in hardware, and the default don’t display;
- To insure of in and out communist is credibility, the failures relate to outdoor unit will
remain failure state for 2 minutes max after recovered.
- In all failures, only sensor failures don’t have to repower to cancel.
- Error list
Failure type = In and out communication failure
LED CODE = RUN,TIMER –both winking
DIGITAL LED CODE = E0
Failure type = Outdoor communication failure
LED CODE = RUN,TIMER –both winking
DIGITAL LED CODE = EC
Failure type = Outdoor sensor
LED CODE = RUN-1 time/8s
DIGITAL LED CODE = E1
Failure type = Indoor coil temperature sensor
LED CODE = RUN-2 times/8s
DIGITAL LED CODE = E2
Failure type = Outdoor coil temperature sensor
LED CODE = RUN-3 times/8s
DIGITAL LED CODE = E3
Failure type = System abnormity
LED CODE = RUN-4 times /8s
DIGITAL LED CODE = E4
Failure type = Type mismatch
LED CODE = RUN-5 times /8s
DIGITAL LED CODE = E5
Failure type = Indoor fan motor
LED CODE = RUN-6 times /8s
DIGITAL LED CODE = E6
Failure type = Outdoor temperature sensor
LED CODE = RUN-7 times /8s
DIGITAL LED CODE = E7
Failure type = Discharge temperature sensor
LED CODE = RUN-8 times /8s
DIGITAL LED CODE = E8
Failure type = Invert module abnormity
LED CODE = RUN-9 times /8s
DIGITAL LED CODE = E9
Failure type = Outdoor fan motor (DC)
LED CODE = RUN-10 times /8s
DIGITAL LED CODE = EF
Failure type = Current sensor
LED CODE = RUN--11 times /8s
DIGITAL LED CODE = EA
Failure type = EEPROM failure
LED CODE = RUN-12 times /8s
DIGITAL LED CODE = EE
Failure type = Top of compressor temperature switch
LED CODE = RUN-13 times /8s
DIGITAL LED CODE = EP
Failure type = Voltage sensor
LED CODE = RUN-14 times /8s
DIGITAL LED CODE = EU
Protection display code list:
Protection type = higher or lower voltage
LED CODE = RUN-winking,TIMER-1 time/8s
DIGITAL LED CODE = P1
Protection type = Over current
LED CODE = RUN- winking,TIMER-2 times /8s
DIGITAL LED CODE = P2
Protection type = Discharge temperature
LED CODE = RUN- winking,TIMER-4 times /8s
DIGITAL LED CODE = P4
Protection type = Over cooling in cooling mode
LED CODE = RUN-light,TIMER-5 times /8s
DIGITAL LED CODE = P5
Protection type = Over heating in cooling mode
LED CODE = RUN- light,TIMER-6 times /8s
DIGITAL LED CODE = P6
Protection type = Over heating in heating mode
LED CODE = RUN- light,TIMER-7 times /8s
DIGITAL LED CODE = P7
Protection type = Outdoor temperature too high or low
LED CODE = RUN- light,TIMER-8 times /8s
DIGITAL LED CODE = P8
Protection type = Drive protection(Overload)
LED CODE = RUN- winking,TIMER-9 times/8s
DIGITAL LED CODE = P9
Protection type = Module self protection
LED CODE = RUN- winking,TIMER-10 times/8s
DIGITAL LED CODE = P0
Outdoor failure display
There is a LED on outdoor power board, when compressor is running; it is normally light;
when no feedback of signal to power board from compressor, it will wink by lighting 1s and
going out 1s. If failures happened, it will light 0.5s, go out 0.5s, winking several times and go
out 3s for a cycle to indicate failures. The failure list is the follow:
Blink times(n) = 1
Failure = IPM protection
Blink times(n) = 2
Failure = higher or lower voltage
Blink times(n) = 3
Failure = Over current
Blink times(n) = 4
Failure = Discharge temperature too high
Blink times(n) = 5
Failure = Outdoor coil temperature too high
Blink times(n) = 6
Failure = Drive abnormity
Blink times(n) = 7
Failure = Communication abnormity with indoor unit
Blink times(n) = 8
Failure = Compressor over heat (switch on top of compressor)
Blink times(n) = 9
Failure = Outdoor air temperature sensor failure
Blink times(n) = 10
Failure = Outdoor coil temperature sensor failure
Blink times(n) = 11
Failure = Outdoor discharge pipe temperature sensor failure
Blink times(n) = 12
Failure = Voltage sensor failure
Blink times(n) = 13
Failure = Current sensor failure
Blink times(n) = 14
Failure = IPM abnormity
Blink times(n) = 15
Failure = Outdoor communication abnormity
Blink times(n) = 16
Failure = DC fan motor no feedback
Blink times(n) = 17
Failure = defrosting
Blink times(n) = 18
Fault Message = Short-circuit / open-circuit fault of intake temperature sensor
Blink times(n) = 19
Fault Message = Outdoor EEPROM fault
Blink times(n) = 20
Fault Message = Outdoor fan motor protection
Blink times(n) = 21
Fault Message = Indoor fan motor protection
Blink times(n) = 23
Fault Message = System in shortage of Freon
Blink times(n) = 24
Fault Message = Model configuration wrong
Blink times(n) = 25
Fault Message = Indoor sensor fault
Blink times(n) = 26
Fault Message = Indoor coil sensor fault
Blink times(n) = 27
Fault Message = Indoor EEPROM fault
Blink times(n) = 28
Fault Message = Indoor fan motor fault
Blink times(n) = 30
Fault Message = drive fault(V4、VP2)
Blink times(n) = 31
Fault Message = Outdoor environmental Over temperature / Under temperature protection
Blink times(n) = 32
Fault Message = Indoor coil defrost prevention
Blink times(n) = 33
Fault Message = Indoor coil overheating protection
28 komentar:
Kalau Indoor Motor failure, solusinya apa ya Mas? Apakah harus ganti? Padahal saya baru beli baru 2 bulan merek TCL
Kerusakan pada fan motor indoornya, kemungkinan fan motornya ampernya besar.
baru beli ac atau ganti fan motor indoor nya?
kalau Ac Standing 5pk merek Akira E6 kerusakan nya dimana boz...?
Error code eo
Error code er
Error code EL
EA error code
E2 code tcl air-con indoor
Error code E4. TCL cassette unit?
Ettore code e5 tcl air conditionné 48000btu
Ea error please how to fix
So how do you solve this problem
Error code CF?
TCL portable air con
Display show dh but still running
What is the possible ?
Blink times(n) = 6
Failure = Drive abnormity
How to resolve???
F7
https://www.youtube.com/channel/UCjUFtXZ-oMCNht6Icj6R6NQhttps://www.youtube.com/channel/UCjUFtXZ-oMCNht6Icj6R6NQ
Tcl errors code And solutions
EASY TO LEARN TECH yt channel
https://youtu.be/z8D3MNXa_rQ
OA error Aya rha ha
Mine just comes on and right back off and says 25 then 25 then 04??
Tcl 10,000 btu blinks pp and stays on with 88 cant find error code what is wrong
How about C2 and nonstop blinking? You have nothing listed for that. If I even try to adjust my temps, my AC will start beeping with that code displaying blinking
CF
What does e9 (invert module abnormity) means? How do I solve/repair it?
Error code (PP)
How about error ff tcl portacool
Timer, winking right through?