Model HSU-09/12HVA103/R2(DB)FOR Eorope
Code = E0
Flash time of
compressor
running
indicate lamp = 10
Trouble contents (old) = drainage system trouble
Trouble contents (new) = drainage system trouble
Code = E1
Flash time of
compressor
running
indicate lamp = 1
Trouble contents (old) = indoor temperature sensor broken
Trouble contents (new) = indoor temperature sensor broken
Code = E2
Flash time of
compressor
running
indicate lamp = 2
Trouble contents (old) = indoor coil temperature sensor broken
Trouble contents (new) = indoor coil temperature sensor broken
Code = E3
Flash time of
compressor
running
indicate lamp = 3
Trouble contents (old) = outdoor temperature sensor broken
Trouble contents (new) = outdoor temperature sensor broken
Code = E4
Flash time of
compressor
running
indicate lamp = 4
Trouble contents (old) = outdoor coil temperature sensor broken
Trouble contents (new) = outdoor coil temperature sensor broken
Code = E5
Flash time of
compressor
running
indicate lamp = 5
Trouble contents (old) = over current protect limit
Trouble contents (new) = over current protect limit
Code = E6
Flash time of
compressor
running
indicate lamp = 6
Trouble contents (old) = pressure protect
Trouble contents (new) = pressure protect
Code = E7
Flash time of
compressor
running
indicate lamp = 7
Trouble contents (old) = communication trouble between wired remote controller and indoor unit.
Trouble contents (new) = three phase protect
Code = E8
Flash time of
compressor
running
indicate lamp = 8
Trouble contents (old) = communication trouble between indoor and outdoor unit.
Trouble contents (new) = Communication trouble between wired remote controller and indoor unit
Code = E9
Flash time of
compressor
running
indicate lamp = 9
Trouble contents (old) = three phase protect
Trouble contents (new) = communication trouble between indoor and outdoor unit
HSU-09/12HVA103/R2(DB)FOR Eorope
Error Codes and Description indoor and outdoor display(1)
Indoor and Outdoor = E7
Indoor Malfunction =
Code indication
Indoor =
Outdoor (LED1 flash times) = 15
Description = Communication fault between indoor and outdoor units
Indoor and Outdoor =
Indoor Malfunction = E1
Code indication
Indoor =
Outdoor (LED1 flash times) =
Description = Room temperature sensor failure
Indoor and Outdoor =
Indoor Malfunction = E2
Code indication
Indoor =
Outdoor (LED1 flash times) =
Description = Heat-exchange sensor failure
Indoor and Outdoor =
Indoor Malfunction = E4
Code indication
Indoor =
Outdoor (LED1 flash times) =
Description = Indoor EEPROM error
Indoor and Outdoor =
Indoor Malfunction = E14
Code indication
Indoor =
Outdoor (LED1 flash times) =
Description = Indoor fan motor malfunction
Indoor and Outdoor =
Indoor Malfunction = E9
Code indication
Indoor =
Outdoor (LED1 flash times) =
Description = High work-E9 intense protection
Error Codes and Description indoor and outdoor display(2)
Outdoor Malfunction
Code Indication
Indoor = F12
Outdoor (LED1 flash times) = 1
Description = Outdoor EEPROM error
Outdoor Malfunction
Code Indication
Indoor = F11
Outdoor (LED1 flash times) = 2
Description = The protection of IPM
Outdoor Malfunction
Code Indication
Indoor = F22
Outdoor (LED1 flash times) = 3
Description = Over current protection of AC electricity for the outdoor model
Outdoor Malfunction
Code Indication
Indoor = F11
Outdoor (LED1 flash times) = 4
Description = Communication fault between the IPM and outdoor PCB
Outdoor Malfunction
Code Indication
Indoor =
Outdoor (LED1 flash times) = 5
Description = Over pressure or Overheat protection for the compressor
Outdoor Malfunction
Code Indication
Indoor = F11
Outdoor (LED1 flash times) = 6
Description = Power voltage is too high or low
Outdoor Malfunction
Code Indication
Indoor = F4
Outdoor (LED1 flash times) = 8
Description = Overheat protection for exhaust temperature
Outdoor Malfunction
Code Indication
Indoor =
Outdoor (LED1 flash times) = 9
Description = outdoor fan motor malfunction
Outdoor Malfunction
Code Indication
Indoor = F21
Outdoor (LED1 flash times) = 10
Description = Frost-removing temperature sensor failure
Outdoor Malfunction
Code Indication
Indoor = F6
Outdoor (LED1 flash times) = 12
Description = Ambient temperature sensor failure
Outdoor Malfunction
Code Indication
Indoor = F25
Outdoor (LED1 flash times) = 13
Description = Exhaust temperature sensor failure
Outdoor Malfunction
Code Indication
Indoor =
Outdoor (LED1 flash times) = 18
Description = deviate from the normal for the compressor
Outdoor Malfunction
Code Indication
Indoor = F11
Outdoor (LED1 flash times) = 19
Description = Loop of the station detect error
Outdoor Malfunction
Code Indication
Indoor = - - -
Outdoor (LED1 flash times) = 24
Description = Over current of the compressor
Outdoor Malfunction
Code Indication
Indoor = - - -
Outdoor (LED1 flash times) = 25
Description = Over current protection for single-past of the compressor