Saturday, November 20, 2010

Fujitsu Inverter Error Codes

0 komentar
To Interrogate
When E:EE is displayed switch unit off and press the temp up and temp down buttons simultaneously for 3 seconds.
To Return to Normal Operation
Press Temp Up and Temp Down Buttons together for 3 seconds.
To Initiate Test Operation
Switch Unit Off & Press Master & Fan Buttons together for 3 seconds.
Press Start/Stop to Initiate.
Changing the Sensor Position
The unit can sense the air temperature at the unit or controller Turn Unit Off To change press THERMOSENSOR button for 5 seconds to unlock
Toggle the THERMOSENSOR button & controller is displayed Set to desired setting (unit or controller)
Press THERMOSENSOR button for 5 seconds to lock

Two Handsets/1 Unit - set on RC DIP SWs
Single handset DIP SW1 is On & 2 is Off
Dual Handset Master Both On & Slave both Off
Group Control up to 16 Unit from 1 RC Handset
Set DIP SW3 on RC to ON
Set Each ID Unit Rotary SW to Unit Address (0-15) in series
Auto Restart on Power Failure
DIP SW2-3 on ID Unit. Off is autorestart (std)/On is manual Restart
Auto Changeover
DIP SW5 on RC. On is autochangeover (std)/Off is Manual
Memory Retention on Power Failure
Dip SW6 on RC. On is Memory/Off is no memory

Wired Remote Control Models
Code Consists of Indoor Unit Address Followed by the Fault Code Below.
No E denotes no fault.
OO ID to RC Comms Fail
O1 ID to OD Comms Fail
O2 ID Air Sensor Open
O3 ID Air Sensor Close
O4 ID Pipe Sensor Open
O5 ID Pipe Sensor Close
O6 OD Pipe Sensor Fail
O8 Power Source Connection Failure
O9 Drain Problem
OA OD Air Sensor Fail
OC Discharge sensor Fail
OE Outdoor High Pressure
11 OD PCB Fail
12 ID Fan Fail
13 OD Signal Abnormal
14 OD EEPROM Fail
15 Compressor Temp Failure
16 Pressure Switch Error
17 IPM Error
18 CT Error
19 Active Filter Module Error
1A Compressor Failure
1B OD Fan Failure
1C Inverter to PCB Comms Fail
1D 2 Way Valve sensor Fail
1E Expansion Valve Error
1F Connection ID Unit Error

Outdoor PCB Fault Codes
Inverter OD Unit PCBs (1 red LED)

OD PCB LED Pulses = 1
Models 9-30 = Comms Failure
Models 36-54 = Comms Failure

OD PCB LED Pulses = 2
Models 9-30 = Disch Sensor Fail
Models 36-54 = Disch Sensor Fail

OD PCB LED Pulses = 3
Models 9-30 = Pipe Sensor Fail
Models 36-54 = Pipe Sensor Fail

OD PCB LED Pulses = 4
Models 9-30 = Air Sensor Fail
Models 36-54 = Air Sensor Fail

OD PCB LED Pulses = 5
Models 9-30 = 2 Way Valve Sensor
Models 36-54 =

OD PCB LED Pulses = 6
Models 9-30 = 3 Way Valve Sensor
Models 36-54 =

OD PCB LED Pulses = 7
Models 9-30 = Compressor Thermistor
Models 36-54 = Compressor Thermistor

OD PCB LED Pulses = 8
Models 9-30 = Pressure Switch
Models 36-54 = Heat Sink Sensor Fail

OD PCB LED Pulses = 9
Models 9-30 = Indoor Comms Error
Models 36-54 = Pressure Switch

OD PCB LED Pulses = 10
Models 9-30 = Current Trip
Models 36-54 =

OD PCB LED Pulses = 11
Models 9-30 = CT Fail
Models 36-54 =

OD PCB LED Pulses = 12
Models 9-30 = Compressor Position Fail
Models 36-54 = IPM Error

OD PCB LED Pulses = 13
Models 9-30 = Compressor Start Fail
Models 36-54 = Compressor Position Fail

OD PCB LED Pulses = 14
Models 9-30 = Timer Failure
Models 36-54 = Compressor Start Fail

OD PCB LED Pulses = 15
Models 9-30 =
Models 36-54 = OD Upper Fan Fail

OD PCB LED Pulses = 16
Models 9-30 =
Models 36-54 = OD Lower Fan Fail

OD PCB LED Pulses = Slow Blink
Models 9-30 =
Models 36-54 = Protect Operation

Non Inverter OD PCBs (2 red LEDs)

LED1 = Blinks
LED2 = Blinks
OD PCB Fail

LED1 = 1 Pulse
LED2 = Lit
Power Source Failure

LED1 = 2 Pulse
LED2 = Lit
OD Disch Temp Sensor

LED1 = 3 Pulse
LED2 = Lit
OD Pipe Sensor

LED1 = 4 Pulse
LED2 = Lit
OD Air Sensor

LED1 = 5 Pulse
LED2 = Lit
Comms Failure

LED1 = 6 Pulse
LED2 = Lit
Indoor Unit Error

LED1 = 7 Pulse
LED2 = Lit
High Discharge Temp

LED1 = 8 Pulse
LED2 = Lit
High Pressure

LED1 = 9 Pulse
LED2 = Lit
Compressor Temp Abnormal

LED1 = 10 Pulse
LED2 = Lit
Compressor Temp Sensor Fail


Inverter Multi AOY30
This has 4 LEDs A,B, C & D to denote which circuit has the fault
Up to 8 flashes - faults are identical to above 9-30 Single System

9 Pressure Switch A
10 Pressure Switch B
11 Indoor Unit Indexing Problem
12 IPM Fail
13 Compressor Position Fail
14 Compressor Fail
15 OD Fan Upper Fail
16 OD Fan Lower Fail
17 PCB Fail

Interconnecting Wiring

CO Multis 2 (Live) 1 (Neutral) 3 (Comms)
HP Multis 1 (Live) 2 (Neutral) 3 (Comms)
AOY90T 3 (Live) 2 (Neutral) 1 (Comms)
ALL OTHERS 1 or L 2 or N 3

We recommend external pumps have their own power supply.
Taking Power for a pump from the unit is a major source of Errors (CLIMATE CENTRE)


Pipework
• Pipe sizes and lengths should be as the relevant Technical Guide
• Both lines should be insulated
• No line accessories or oil traps should be fitted
• In cooling mode both pipes should be between 0 and 10C - the suction line should sweat, but not freeze
• In heating moded both pipes should be between 30 an 60C
• Pipework should be refrigeration quality
• Refrigerant should be R22, unless stated on the outdoor unit
• Look for restrictions. They could cause compressor failures.
Outdoor Unit
• Discharge temperature should be between 50 & 70C
• Suction temperature should be between -3 & 4C
• If fan switches off check for high discharge temperature
• Check Suction Line is sweating – problem if not!
• Hot Recip. Compressor = PROBLEM!
• Sweating/Frost on expansion line – undercharged
Indoor Unit
• Is it level? Have we adequate drainage?
• Smells are always due to site conditions or drains
• Flashing lights? = Fault Diagnostics - see over
• When were the filters last cleaned?
• Is the unit too large/small (between 5/20 air circs / hr)
• Is it on Timer/Test Mode
Controller
• EE:EE on LCD handset - fault diagnostics - see over
• Is the handset too far away?
• When were the batteries changed last?
• Heat Pump models 7-14 – NOT auto changeover
• Timer is one shot, unless it has ‘repeat’ mode
• With wired handset, check for interference. Cable should be screened
• Is it on Timer/Test Mode
Wiring
• In general interconnecting wiring is 240 Volt, but see chart for details
• With LCD wired handset models, Terminal 3 is the Live Not Terminal 1
NEVER apply mains voltage to Terminal 1 on these models
• With LCD wired handset models wiring should be screened
• Check Voltage drops! Check it isn’t down to Earth!
• Has it got a timeclock/BMS interface?
• Interconnecting cables MUST be circular crimped

What the separate Wires do in the interconnecting Cables
Note – Wires are 240V Live except where marked neutral or Earth or signal
Cables marked Signal are digital pulses and you should not attempt to measure these with a meter.


Wired Controllers - Fault diagnostics
A Fault Condition is signalled by EE:EE appearing on the LCD panel.
The unit should be interrogated by switching it off on the handset then
pressing either the down arrows on the SET TIME and TEMP/DAY buttons
together for 3 seconds for 7 day models or the ENERGY SAVE & ZONE
CONTROL buttons for other models.
The Failure code is in 2 parts - Fault and Address.
The Fault Code is an E code. The second is the unit address for multi
linked systems - with single units this is always 00. 7 day models have the
fault code as shown in the table below above the address.
Other models have the codes below, minus the 0, followed by the address
- e.g. E9:00 denoting Float Switch on Unit 0.

Code = E:0
Fault = I/U - R/C Comms
Diagnosis = Check R/C wiring. Interference?

Code = E:01
Fault = I/U - O/U Comms
Diagnosis = Check intercon. wiring. Interference

Code = E:02
Fault = Room Sensor Open
Diagnosis = Sensor Missing

Code = E:03
Fault = Room Sensor Short
Diagnosis = Sensor Faulty

Code = E:04
Fault = I/U Pipe Sensor Open
Diagnosis = Sensor Missing

Code = E:05
Fault = I/U Pipe Sensor Short
Diagnosis = Sensor Faulty

Code = E:06
Fault = O/U Pipe Sensor Open
Diagnosis = Sensor Missing

Code = E:07
Fault = O/U Pipe Sensor Short
Diagnosis = Sensor Faulty

Code = E:08
Fault = Power Source Error
Diagnosis = Incorrect Power Supply

Code = E:09
Fault = Float Switch
Diagnosis = Check Drains - High Water Level

Code = E:0A
Fault = O/U Air Sensor Open
Diagnosis = Sensor Missing

Code = E:0C
Fault = Disch Sensor Open
Diagnosis = Sensor Missing

Code = E:0D
Fault = Disch Sensor Short
Diagnosis = Sensor Faulty

Code = E:0F
Fault = High Disch Temp
Diagnosis = Contamination In Pipework/Gas Shortage

Code = E:11
Fault = Model Abnormal
Diagnosis = Check PCB compatability

Code = E:12
Fault = Indoor Fan Failure
Diagnosis = Check Fan and Motor

Code = E:13
Fault = O/D Signal Abnormal
Diagnosis = Communications?

Code = E:14
Fault = Outdoor PCB Fail
Diagnosis = PCB Failure

Outdoor Unit with
A fault condition is signified by flashing red LED’s on the the outdoor PCB
if it is equipped with one. Except for multisplits and 2 LED models, the
diagnostics are shown in the table on the right.
For 2 LED models flashing signifies sensor failure and constantly lit
indicates high discharge temperature.

Fault = Signal Failure
LED1 =
LED2 =
LED3 =
LED4 = Flash
LED5 =
LED6 =

Fault = Indoor Unit Failure
LED1 =
LED2 =
LED3 =
LED4 = Flash
LED5 =
LED6 =

Fault = Discharge Sensor Fail
LED1 =
LED2 =
LED3 =
LED4 =
LED5 =
LED6 = Flash

Fault = O/D Pipe Sensor Fail
LED1 =
LED2 =
LED3 =
LED4 =
LED5 = Flash
LED6 = Flash

Fault = O/D Air Sensor Fail
LED1 =
LED2 =
LED3 = Flash
LED4 =
LED5 = Flash
LED6 =

Fault = Power Source Error
LED1 =
LED2 = Flash
LED3 =
LED4 =
LED5 =
LED6 =

Fault = PCB
LED1 = Flash
LED2 = Flash
LED3 = Flash
LED4 = Flash
LED5 = Flash
LED6 = Flash

Fault = PCB Failure
LED1 = *
LED2 = *
LED3 = *
LED4 = *
LED5 = *
LED6 = * All Flashing Very Rapidly

Fault = High Pressure Trip
LED1 = Flash
LED2 =
LED3 =
LED4 =
LED5 =
LED6 =

Fault = Discharge Temp Trip
LED1 =
LED2 = Flash
LED3 =
LED4 =
LED5 =
LED6 =




Unit = All
Code Means:- = Power On
Red = On
Green = Off
Yellow = Off

Unit = All
Code Means:- = Timer Mode
Red = On
Green = On
Yellow = Off

Unit = All
Code Means:- = Louvre On
Red = On
Green = On or Off
Yellow = On

Unit = All
Code Means:- = HP Defrost Cont.
Red = Long pulses
Green = Off
Yellow = Off

Unit = All
Code Means:- = Test
Red = Cont. Pulse
Green = Cont. Pulse
Yellow = Off

Unit = D,E,F
Code Means:- = Power Fail
Red = On
Green = Cont Long
Yellow = Pulses Off

Unit = All
Code Means:- = PCB Failure
Red = Cont. Short Pulse
Green = Cont. Short Pulse
Yellow = Off

Unit = G
Code Means:- = Room Sensor Fault
Red = 1 Short Pulse
Green = Rapid Pulse
Yellow = Off

Unit = A,B,G
Code Means:- = Sensor Fault
Red = 2 Short Pulses
Green = Rapid Pulse
Yellow = Off

Unit = D,E,F
Code Means:- = Room Sensor Open/Fail
Red = 2 Short Pulses
Green = Rapid Pulse
Yellow = Off

Unit = E,F
Code Means:- = Room Sensor Short
Red = 2 Short Pulses
Green = Rapid Pulse
Yellow = Rapid Pulse

Unit = C
Code Means:- = Room Sensor Fault
Red = 3 Short Pulses
Green = Long Pulse
Yellow = Off

Unit = D,E,F
Code Means:- = Pipe Sensor Open
Red = 3 Short Pulses
Green = Rapid Pulse
Yellow = Off

Unit = E,F
Code Means:- = Pipe Sensor Short
Red = 3 Short Pulses
Green = Rapid Pulse
Yellow = Rapid Pulse

Unit = D,E,F
Code Means:- = High Water
Red = 4 Short Pulse
Green = Rapid Pulse
Yellow = Off

Unit = F
Code Means:- = Comms Failure
Red = 5 Short Pulses
Green = Rapid Pulse
Yellow = Off

Unit = G
Code Means:- = High Water
Red = 6 Short Pulses
Green = Rapid Pulse
Yellow = Off

Unit = B,E,F
Code Means:- = Fan Failure
Red = 6 Short Pulses
Green = Rapid Pulse
Yellow = Off

Unit = F
Code Means:- = 3ph Reversal
Red = Rapid Pulse
Green = 2 Short Pulses
Yellow = Off

Unit = C
Code Means:- = Pipe Sensor Fault
Red = Long Pulse
Green = 3 Short Pulses
Yellow = Off

Unit = F OD
Code Means:- = Pipe Sensor Open
Red = Rapid Pulse
Green = 3 Short Pulses
Yellow = Off

Unit = F OD
Code Means:- = Pipe Sensor Short
Red = Rapid Pulse
Green = 3 Short Pulses
Yellow = Rapid Pulse

Unit = F OD
Code Means:- = Temp Sensor Open
Red = Rapid Pulse
Green = 4 Short
Yellow = Pulses Off

Unit = F OD
Code Means:- = Temp Sensor Short
Red = Rapid Pulse
Green = 4 Short Pulses
Yellow = Rapid Pulse

Unit = F
Code Means:- = Discharge Sensor Open
Red = Rapid Pulse
Green = 5 Short Pulses
Yellow = Off

Unit = F
Code Means:- = Discharge Sensor Short
Red = Rapid Pulse
Green = 5 Short Pulses
Yellow = Rapid Pulse

Unit = F
Code Means:- = High/Low Pressure
Red = Rapid Pulse
Green = 6 Short Pulses
Yellow = Off

Unit = F
Code Means:- = High Discharge Temp
Red = Rapid Pulse 7
Green = Short Pulses
Yellow = Off

SENSOR RESISTANCES - Use to Check Thermistors across the range

Sensor At 10C At 20C At 30C
Air Temperature Sensors 20K Ohms 13K Ohms 8K Ohms
Indoor Pipe Sensor 103K Ohms 63K Ohms 40K Ohms
Outdoor Pipe Sensor 10K Ohms 6K Ohms 4K Ohms
Discharge Sensor 646K Ohms 395K Ohms 250K Ohms
Read More ->>

Thursday, November 18, 2010

Samsung BAC Error Codes

0 komentar
Universal Outdoor Unit Inverter Error Codes

Error Code = 101
Explanation and Checking points = Indoor unit communication error - check wiring

Error Code = 102
Explanation and Checking points = Indoor/outdoor unit communication time our error

Error Code = 201
Explanation and Checking points = Indoor unit is not connected

Error Code = 203
Explanation and Checking points = Communication error between outdoor main PCB and Inverter

Error Code = 121
Explanation and Checking points = Indoor temp. sensor (open/short) - check and replaced if required

Error Code = 122
Explanation and Checking points = Indoor unit pipe in sensor (open/short) - check and replaced if required

Error Code = 128
Explanation and Checking points = Indoor unit pipe in sensor separation

Error Code = 221
Explanation and Checking points = Outdoor temp. sensor error (open/short) - check and replaced if required

Error Code = 237
Explanation and Checking points = COND temp. sensor error (open/short) - check and replaced if required

Error Code = 260
Explanation and Checking points = Inverter compressor discharge temp. sensor error (open/short)

Error Code = 153
Explanation and Checking points = Indoor float switch error

Error Code = 460
Explanation and Checking points = Outdoor unit-indoor unit communication error

Error Code = 554
Explanation and Checking points = Outdoor unit refrigerant leakage (gas leak)

Error Code = 458
Explanation and Checking points = Outdoor unit fan error

Error Code = 461
Explanation and Checking points = Inverter compressor start failure

Error Code = 464
Explanation and Checking points = Inverter DC PEAK Error

Error Code = 466
Explanation and Checking points = Inverter DC LINK Voltage 150V below, 410V Over

Error Code = 467
Explanation and Checking points = Inverter compressor rotation error

Error Code = 468
Explanation and Checking points = Inverter current sensor error

Error Code = 469
Explanation and Checking points = Inverter DC LINK sensor error

Error Code = 471
Explanation and Checking points = Inverter EEPROM read/write error

Error Code = 472
Explanation and Checking points = Inverter error

Error Code = 556
Explanation and Checking points = Outdoor unit capacity setup option error

Error Code = 601
Explanation and Checking points = Wired liquid crystal - indoor unit comm. error

Error Code = 602
Explanation and Checking points = Master wired liquid crystal - slave liquid crystal comm. error

Error Code = 603
Explanation and Checking points = Wired liquid crystal COM1/COM2 cross error

Error Code = 604
Explanation and Checking points = Error of setting option for wired remote controller COM2
Read More ->>

Samsung RAC and FJM Fault Codes

0 komentar
Samsung RAC and FJM Fault Codes


Operation =
Flashing Display Timer = Yes
Turbo =
LED Display = E1
Explanation and Checking points = Indoor unit room thermistor error - Open or Closed Circuit - Check and replace if required

Operation = Yes
Flashing Display Timer = Yes
Turbo =
LED Display = E2
Explanation and Checking points = Indoor unit pipe thermistor error - - Open or Closed Circuit - Check and replace if required


Operation =
Flashing Display Timer =
Turbo = Yes
LED Display = E3
Explanation and Checking points = Indoor unit fan motor malfunction - Check and replace if required


Operation =
Flashing Display Timer = Yes
Turbo = Yes
LED Display = E6
Explanation and Checking points = EPROM error - Check and replace PCB if required


Operation = Yes
Flashing Display Timer = Yes
Turbo = Yes
LED Display = Flashing
Explanation and Checking points = Option code error - Check and input new option code if required via wireless remote controller


Operation = Yes
Flashing Display Timer =
Turbo = Yes
LED Display =
Explanation and Checking points = Outdoor unit temperature sensor - Open or Closed Circuit - Check and replace if required

Outdoor Unit

Error Code = Er - E1
Explanation and Checking points = Indoor unit room temperature sensor error (open/short) - Check and replace if required

Error Code = Er - E5
Explanation and Checking points = Indoor unit heat exchanger out temperature sensor error (open/short) - Check and replace if required

Error Code = Er - 05
Explanation and Checking points = Indoor unit heat exchanger in temperature sensor error (open/short) - Check and replace if required

Error Code = Er - 06
Explanation and Checking points = EPROM error - Check and replace PCB if required

Error Code = Er - 09
Explanation and Checking points = Option code error - Check and input new option code if required via wireless remote controller

Error Code = E3 - 01
Explanation and Checking points = Indoor fan motor malfunction Fan and cable - Check and replace if required

Error Code = Er - 01
Explanation and Checking points = Communication error between the indoor unit and outdoor unit

Error Code = Er - 11
Explanation and Checking points = Abnormal increase of operation current

Error Code = Er - 12
Explanation and Checking points = Abnormal increase of OLP temperature

Error Code = Er - 13
Explanation and Checking points = Abnormal increase of discharge temperature

Error Code = Er - 14
Explanation and Checking points = Over current of IPM circuit Comp. Fan

Error Code = Er - 15
Explanation and Checking points = Abnormal increase of heat sink temperature Fan

Error Code = Er - 10
Explanation and Checking points = BLCD compressor starting error Comp. PCB, Comp wire

Error Code = Er - E6
Explanation and Checking points = deice temp-sensor - Check and replace if required

Error Code = Er - 31
Explanation and Checking points = outdoor temp-sensor - Check and replace if required

Error Code = Er - 32
Explanation and Checking points = discharge temp-sensor - Check and replace if required

Error Code = Er - 33
Explanation and Checking points = discharge temp-sensor - Check and replace if required

Error Code = Er - 17
Explanation and Checking points = Communication error between 2 micom on the outdoor PCB

Error Code = Er - 36
Explanation and Checking points = current sensor error PCB - Check and replace if required

Error Code = Er - 37
Explanation and Checking points = heatsink temp-sensor error PCB - Check and replace if required

Error Code = Er - 38
Explanation and Checking points = Voltage sensor error - Check and replace if required


Inverter Unit

Display = E1 01
Explanation and Checking points = Communication error (indoor unit unable to receive data) - Check cables

Display = E1 02
Explanation and Checking points = Communication error (outdoor unit unable to communicate) - Check addresses

Display = E1 21
Explanation and Checking points = Indoor unit room temperature sensor error (Open/Short) - Check and replace if required

Display = E1 22
Explanation and Checking points = Indoor unit sensor error - Evaporator pipe in sensor error (Open/Short) - Check and replace if required

Display = E1 23
Explanation and Checking points = Indoor unit sensor error - Evaporator pipe out sensor error (Open/Short) - Check and replace if required

Display = E1 28
Explanation and Checking points = Indoor unit sensor error - Evaporator pipe out sensor detached

Display = E1 30
Explanation and Checking points = Indoor unit heat exchanger in & out temperature sensor detached

Display = E1 54
Explanation and Checking points = Indoor unit fan malfunction

Display = E1 61
Explanation and Checking points = More than 2 indoor units cool and heat simultaneously

Display = E1 62
Explanation and Checking points = EPROM error

Display = E1 63
Explanation and Checking points = Option code setting error

Display = E1 85
Explanation and Checking points = Cable miss wiring

Display = E2 01
Explanation and Checking points = The number of indoor unit mismatched

Display = E2 02
Explanation and Checking points = Communication error (outdoor unable to receive data)

Display = E2 03
Explanation and Checking points = Communication error between two microcontroller on the outdoor PCB

Display = E2 21
Explanation and Checking points = Outdoor temperature sensor error (Short/Open) - Check and replace if required

Display = E2 37
Explanation and Checking points = Condenser temperature sensor error (Short/Open) - Check and replace if required

Display = E2 46
Explanation and Checking points = Condenser temperature sensor detached

Display = E2 51
Explanation and Checking points = Compressor discharge sensor error (Short/Open) - Check and replace if required

Display = E2 59
Explanation and Checking points = Outdoor unit error

Display = E2 60
Explanation and Checking points = Compressor discharge sensor error (Short/Open) - Check and replace if required

Display = E2 61
Explanation and Checking points = Compressor discharge sensor detached

Display = E3 20
Explanation and Checking points = Compressor OLP sensor error (Short/Open) - Check and replace if required

Display = E4 01
Explanation and Checking points = Indoor unit heat exchanger freezing and compressor stop (cooling mode)

Display = E4 04
Explanation and Checking points = Outdoor unit overload and compressor stop (protection control in heating mode)

Display = E4 16
Explanation and Checking points = Outdoor unit high discharge temperature and compressor stop (heating mode)

Display = E4 19
Explanation and Checking points = Outdoor unit EEV open error (self diagnosis) - Check and replace if required

Display = E4 22
Explanation and Checking points = Outdoor unit EEV close error (self diagnosis) - Check and replace if required

Display = E4 40
Explanation and Checking points = High temperature (over 30°C) of outdoor as heating mode

Display = E4 41
Explanation and Checking points = Low temperature (under -5°C) of indoor as cooling mode

Display = E4 60
Explanation and Checking points = Wrong connection between communication and power cable

Display = E4 61
Explanation and Checking points = Inverter compressor starting failure (5 times)

Display = E4 62
Explanation and Checking points = Compressor trip by input current limit control

Display = E4 63
Explanation and Checking points = Compressor trip by OLP temperature limit control

Display = E4 64
Explanation and Checking points = Compressor peak current protection

Display = E4 65
Explanation and Checking points = Compressor overload protection by current

Display = E4 66
Explanation and Checking points = DC-link voltage error (under 150V or over 410V)

Display = E4 67
Explanation and Checking points = Compressor rotation error

Display = E4 68
Explanation and Checking points = Current sensor error - Check and replace if required

Display = E4 69
Explanation and Checking points = DC-link voltage sensor error - Check and replace if required

Display = E4 70
Explanation and Checking points = Compressor overload protection - Check refrigerant charge and heat exchangers

Display = E4 71
Explanation and Checking points = EPROM error - Check and replace PCB if required

Display = E4 72
Explanation and Checking points = AC line zero-crossing detection circuit error - Check power supply

Display = E5 54
Explanation and Checking points = No refrigerant error (self diagnosis) - Check refrigerant charge
Read More ->>
 