Error code = E1
Error = Compressor high pressure protection
Error code = E2
Error = Indoor anti-freeze protection
Error code = E3
Error = Compressor low pressure protection, refrigerant lack protection and refrigerant colleting mode
Error code = E4
Error = Compressor air discharge high-temperature protection
Error code = E6
Error = Communication error
Error code = E8
Error = Indoor fan error
Error code = E9
Error = Water-full protection
Error code = F0
Error = Indoor ambient temperature sensor error
Error code = F1
Error = Evaporator temperature sensor error
Error code = F2
Error = Condenser temperature sensor error
Error code = F3
Error = Outdoor ambient temperature sensor error
Error code = F4
Error = Discharge temperature sensor error
Error code = F5
Error = Wired control temperature sensor error
Error code = C5
Error = IDU jumper cap error
Error code = EE
Error = IDU or ODU memory chip error
Error code = PF
Error = Electric box sensor error
Error code = H3
Error = Compressor overload protection
Error code = H4
Error = Overload
Error code = H5
Error = IPM protection
Error code = H6
Error = DC fan error
Error code = H7
Error = Driver out-of-step protection
Error code = HC
Error = Pfc protection
Error code = Lc
Error = Startup failure
Error code = Ld
Error = Compressor phase-sequence protection
Error code = LF
Error = Power protection
Error code = Lp
Error = IDU and ODU unmatched
Error code = U7
Error = 4–way valve switch-over error
Error code = P0
Error = Driver reset protection
Error code = P5
Error = Over-current protection
Error code = P6
Error = Master control and driver communication error
Error code = P7
Error = Driver module sensor error
Error code = P8
Error = Driver module high temperature protection
Error code = P9
Error = Zero-crossing protection
Error code = PA
Error = AC current protection
Error code = Pc
Error = Driver current error
Error code = Pd
Error = Sensor connection protection
Error code = PE
Error = Temperature drift protection
Error code = PL
Error = Bus low-voltage protection
Error code = PH
Error = Bus high-voltage protection
Error code = PU
Error = Charge loop error
Error code = PP
Error = Input voltage error
Error code = ee
Error = Drive memory chip error
Error code = C4
Error = ODU jumper cap error
Error code = dJ
Error = Phase-loss and anti-phase protection
Error code = oE
Error = ODU error, for specific error please see the status of ODU indicator
Error code = EL
Error = Emergency stop (fire alarm)
5 komentar:
nice and great blog..
Heat Pump Wall Mount Air Handler
thanks for informative contentWallpaper in Canada
410a is considered to be more energy-efficient and eco-friendly, which may justify its higher cost in the long run. The 410a refrigerant price can vary depending on several factors such as location, supplier, and the quantity purchased.
فني تركيب وتصليح الادوات الصحية افضل معلم صحي بالكويت خدمات فني صحي الكويت حل مشاكل السباكة والصرف الصحى صحي جمعية بالكويت لاعمال السباكة والصرف طرق حل مشاكل السباكة والصرف الصحي اعمال السباكة والصرف الصحي في الكويت الجمعيات الاهلية وحل مشكلات السباكة والصرف في الكويت مناطق تغطية فني تسليك المجاري بالكويت حل مشكلات السباكة بابسط الطرق