Heat Pump
Indoor Units
FTXR28EV1B
FTXR42EV1B
FTXR50EV1B
Outdoor Units
RXR28EV1B
RXR42EV1B
RXR50EV1B
Code = Basic Failure Diagnosis
Unit = Basic Failure Diagnosis
Description = Air conditioner does not run.
Code = Basic Failure Diagnosis
Unit = Basic Failure Diagnosis
Description = Air conditioner runs but does not get cooling (heating)
Code = Basic Failure Diagnosis
Unit = Basic Failure Diagnosis
Description = When operation starts, safety breaker works.
Code = Basic Failure Diagnosis
Unit = Basic Failure Diagnosis
Description = Air conditioner makes big noise and vibration.
Code = Basic Failure Diagnosis
Unit = Basic Failure Diagnosis
Description = Air does not humidified enough
Code = A1
Unit = Indoor
Description = Indoor unit PCB fault
Code = A5
Unit = Indoor
Description = Peak-cut control or freeze-up protection
Code = A6
Unit = Indoor
Description = Fan motor system fault
Code = AH
Unit = Indoor
Description = Streamer unit fault
Code = C4
Unit = Indoor
Description = Indoor heat exchanger thermistor fault
Code = C7
Unit = Indoor
Description = Front panel open / close fault
Code = C9
Unit = Indoor
Description = Room temperature thermistor fault
Code = CC
Unit = Indoor
Description = Humidity sensor fault
Code = E1
Unit = Outdoor
Description = Outdoor unit PCB fault
Code = E5
Unit = Outdoor
Description = OL activation (compressor overload)
Code = E6
Unit = Outdoor
Description = Compressor lock
Code = E7
Unit = Outdoor
Description = DC fan lock
Code = E8
Unit = Outdoor
Description = Input overcurrent detection
Code = EA
Unit = Outdoor
Description = Four way valve fault
Code = F3
Unit = Outdoor
Description = Discharge pipe temperature control
Code = F6
Unit = Outdoor
Description = High pressure control in cooling
Code = H0
Unit = Outdoor
Description = Compressor sensor system fault
Code = H1
Unit = Humidifying unit
Description = Damper fault
Code = H6
Unit = Outdoor
Description = Position sensor fault
Code = H8
Unit = Outdoor
Description = DC voltage / DC current sensor fault
Code = H9
Unit = Outdoor
Description = Outdoor air thermistor fault
Code = J3
Unit = Outdoor
Description = Discharge pipe thermistor fault
Code = J6
Unit = Outdoor
Description = Outdoor heat exchanger thermistor fault
Code = L3
Unit = Outdoor
Description = Abnormal temperature in electrical box
Code = L4
Unit = Outdoor
Description = Temperature rise in radiation fin
Code = L5
Unit = Outdoor
Description = Output overcurrent
Code = P4
Unit = Outdoor
Description = Radiation fin thermistor fault
Code = P9
Unit = Humidifying unit
Description = Fan motor system fault / fan lock
Code = PA
Unit = Humidifying unit
Description = Heater wire fault
Code = PH
Unit = Humidifying unit
Description = Humidification fan outlet thermistor fault / abnormal heater temperature
Code = U0
Unit = System
Description = Insufficient gas
Code = U2
Unit = System
Description = Over voltage protection (OVP) / low voltage protection (LVP)
Code = U4
Unit = System
Description = Signal transmission error (indoor unit - outdoor unit)
Code = U4
Unit = Outdoor
Description = Outdoor unit PCB fault or communication circuit fault
Code = U7
Unit = System
Description = Signal transmission error on outdoor unit PCB
Code = UA
Unit = System
Description = Incompatible power supply between indoor unit and outdoor unit
Code = UA
Unit = Indoor
Description = Incomplete setting for hose length
Code = -
Unit = System
Description = Lights-out of microcomputer status lamp