ERR 0 = ON
ERR 1 = OFF
ERR 2 = OFF
ERR 3 = ON
Error Contents = Sensor for compressor discharge temp
Error Monitor Lamp
ERR 0 = OFF
ERR 1 = ON
ERR 2 = OFF
ERR 3 = ON
Error Contents = Sensor for heat excharge temp
Error Monitor Lamp
ERR 0 = ON
ERR 1 = OFF
ERR 2 = OFF
ERR 3 = OFF
Error Contents = Sensor for branch pipe A (Narrow tube)
Error Monitor Lamp
ERR 0 = OFF
ERR 1 = ON
ERR 2 = OFF
ERR 3 = OFF
Error Contents = Sensor for branch pipe B (Narrow tube)
Error Monitor Lamp
ERR 0 = ON
ERR 1 = ON
ERR 2 = OFF
ERR 3 = OFF
Error Contents = Sensor for branch pipe C (Narrow tube)
Error Monitor Lamp
ERR 0 = OFF
ERR 1 = OFF
ERR 2 = ON
ERR 3 = OFF
Error Contents = Sensor for branch pipe D (Narrow tube)
Error Monitor Lamp
ERR 0 = ON
ERR 1 = ON
ERR 2 = OFF
ERR 3 = ON
Error Contents = Outdoor temp sensor
Error Monitor Lamp
ERR 0 = ON
ERR 1 = OFF
ERR 2 = ON
ERR 3 = OFF
Error Contents = Sensor for branch pipe A (Wide tube)
Error Monitor Lamp
ERR 0 = OFF
ERR 1 = ON
ERR 2 = ON
ERR 3 = OFF
Error Contents = Sensor for branch pipe B (Wide tube)
Error Monitor Lamp
ERR 0 = ON
ERR 1 = ON
ERR 2 = ON
ERR3 = OFF
Error Contents = Sensor for branch pipe C (Wide tube)
Error Monitor Lamp
ERR 0 = OFF
ERR 1 = OFF
ERR 2 = OFF
ERR 3 = ON
Error Contents = Sensor for branch pipe D (Wide tube)
Error Monitor Lamp
ERR 0 = OFF
ERR 1 = OFF
ERR 2 = ON
ERR 3 = ON
Error Contents = HIC circuit trouble (current, temp)
Error Monitor Lamp
ERR 0 = OFF
ERR 1 = ON
ERR 2 = ON
ERR 3 = ON
Error Contents = Actuation of comp over load relay
Error Monitor Lamp
ERR 0 = ON
ERR 1 = OFF
ERR 2 = ON
ERR 3 = ON
Error Contents = Actuation of freeze protection function
Error Monitor Lamp
ERR 0 = ON
ERR 1 = ON
ERR 2 = ON
ERR 3 = ON
Error Contents = Outdoor unit error. Detail of error message indicate on indoor LED